A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Permanent pacemaker dependency in patients with new left bundle branch block and new first degree atrioventricular block after transcatheter aortic valve implantation. | LitMetric

Conduction disorders with need for permanent pacemaker (PPM) implantation remain frequent complications after transcatheter aortic valve implantation (TAVI). Up to 22% of PPM after TAVI are implanted for new onset left bundle branch block (LBBB) and atrioventricular block (AVB) I. However, clinical benefit and predictors of ventricular pacing in TAVI patients receiving PPM for this indication remain unclear. We retrospectively evaluated pacemaker interrogation data of patients who received a PPM post TAVI for new LBBB and new AVB I. The primary endpoint of this study was relevant ventricular pacing (ventricular pacing rate: Vp ≥ 1%) at the first outpatient pacemaker interrogation. Secondary endpoints were predictors for relevant ventricular pacing. At the first pacemaker interrogation (median follow up at 6.23 [2.8-14.8] months), median ventricular pacing frequency was 1.0% [0.1-17.8]. Out of 61 patients, 36 (59%) had Vp rates ≥ 1%. Patients with frequent ventricular pacing showed longer QRS duration (155 ms ± 17 ms vs. 144 ms ± 18 ms, p = 0.018) at the time of PPM implantation and were less likely treated with a balloon-expandable Edwards Sapiens Valve (39% vs. 12%, p = 0.040). Our findings suggest that the majority of patients with new LBBB and new AVB I after TAVI show relevant ventricular pacing rates at follow up. Further prospective studies are necessary to identify patients at higher risk of pacemaker dependency.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8692410PMC
http://dx.doi.org/10.1038/s41598-021-03667-0DOI Listing

Publication Analysis

Top Keywords

ventricular pacing
28
pacemaker interrogation
12
relevant ventricular
12
permanent pacemaker
8
pacemaker dependency
8
left bundle
8
bundle branch
8
branch block
8
atrioventricular block
8
transcatheter aortic
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!