A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 144

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 144
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 212
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1002
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3142
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Pushing the boundaries of accuracy and reliability during stereotactic procedures: A prospective study on 526 biopsies comparing the frameless robotic and Image-Guided Surgery systems. | LitMetric

Introduction: A 12-year long, prospective, single center study was conducted, comparing two frameless systems for brain biopsies: ROSA robotic-assisted stereotaxy and BrainLab Varioguide image-guided stereotaxy (Image Guided Surgery, IGS).

Method: All consecutive adult and pediatric patients undergoing frameless brain biopsies were included. Successfully achieving diagnosis was the primary endpoint, analysis of all periprocedural complications was the secondary endpoint, and the tertiary endpoint was the length of the procedure, with the aim of assessing of the learning curve for each operator over time. The results for the ROSA robot and the Varioguide system were compared and benchmarked to data from the literature.

Results: We performed 526 on 516 patients, 314 with the ROSA robot (Group A) and 212 with the IGS Varioguide (Group B). Histological diagnosis was achieved in 97.4% of cases in Group A, versus 93.3% in Group B (p < 0.05). No statistically significant difference was found for secondary and tertiary endpoints. The complication rate appeared similar between the 2 frameless systems, with a hemorrhagic complications rate of 3.5% in Group A and 4.7% in Group B. Permanent neurological deterioration was only recorded in 0.8% of cases from Group B. Mortality was recorded in 0.3% in Group A and 0.4% in Group B.

Conclusion: This study provides evidence to confirm that robotic surgery lives up to its promises of increased safety, accuracy, and reliability.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jocn.2021.11.034DOI Listing

Publication Analysis

Top Keywords

comparing frameless
8
brain biopsies
8
rosa robot
8
pushing boundaries
4
boundaries accuracy
4
accuracy reliability
4
reliability stereotactic
4
stereotactic procedures
4
procedures prospective
4
prospective study
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!