A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

On-line Sequencing of CRISPR Guide RNAs and Their Impurities the Use of Immobilized Ribonuclease Cartridges Attached to a 2D/3D-LC-MS System. | LitMetric

On-line Sequencing of CRISPR Guide RNAs and Their Impurities the Use of Immobilized Ribonuclease Cartridges Attached to a 2D/3D-LC-MS System.

Anal Chem

Small Molecule Analytical Chemistry, Genentech, 1 DNA Way, South San Francisco, California 94080, United States.

Published: January 2022

In this study, for the first time, the automated digestion and sequencing of an RNA molecule the use of immobilized RNase cartridges attached to a multidimensional liquid chromatography (LC)-mass spectrometry (MS) system are presented. We first developed an on-line digestion-HILIC two-dimensional (2D)-LC-MS method in order to sequence CRISPR guide RNAs for gene editing. Three RNases (T1, A, and U2) were immobilized on polyetheretherketone cartridges, and their performance was evaluated. Ultrafast digestions were performed within 2.3 min with the on-line approach 30 min the conventional off-line approach. The higher sequence coverage was achieved by the RNase T1 (71%), which is the same as the off-line mode. A 20-fold reduction in the gRNA sample amount was achieved with the on-line digestion approach (6.5 μg) in comparison to that with the off-line approach (130 μg). In the second step, a three-dimensional (3D)-LC-MS method was developed for the sequencing of fractions collected on-line across the main peak and the partially separated tail by the reference ion-pairing RPLC method. Additional insights were gained in order to better understand the cause of the main peak tailing.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.analchem.1c04350DOI Listing

Publication Analysis

Top Keywords

crispr guide
8
guide rnas
8
cartridges attached
8
off-line approach
8
main peak
8
on-line
5
on-line sequencing
4
sequencing crispr
4
rnas impurities
4
impurities immobilized
4

Similar Publications