Objective: The objective of this study was to evaluate the effect of the rapid palatal expansion (RPE) on the pterygoid process (PP), spheno-occipital synchondrosis (SOS) and sella turcica (ST) in the skull of a patient with transversal maxillary collapse, and identify the distribution of mechanical stresses and displacement, by finite element analysis (FEA).

Methods: Cone-beam computed tomography (CBCT) was employed to examine the skull of a patient in this study. The patient was a 13-year-old boy, with Class II skeletal relationship due to transverse atresia and maxillary protrusion. The computer-aided design (CAD) geometry of skull was imported into the SimLab v. 13.1 software, to build the finite element mesh. For the simulation, a displacement of 1 mm, 3 mm and 5 mm in a transverse direction was defined at the midpalatal suture, thereby representing the RPE. For the analysis of results, maximum principal stress (MPS) and displacements were evaluated by identifying different nodes, which were represented by the points as per the areas of interest in the study.

Results: In MPS, the maximum tensile stress was found at point 2 (366.50 MPa) and point 3 (271.50 Mpa). The maximum compressive stress was found at point 8 (-5.84 Mpa). The higher displacements in the transversal plane and the lateral segment were located at point 1 (2.212 mm), point 2 (0.903 mm) and point 3 (0.238 mm).

Conclusions: RPE has a direct effect on PP, SOS and ST in the Class II model skeletal relationship with a transversal maxillary collapse. PP supported a higher tensile stress and displacement.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8690457PMC
http://dx.doi.org/10.1590/2177-6709.26.6.e2120162.oarDOI Listing

Publication Analysis

Top Keywords

finite element
12
rapid palatal
8
palatal expansion
8
element analysis
8
skull patient
8
transversal maxillary
8
maxillary collapse
8
skeletal relationship
8
tensile stress
8
stress point
8

Similar Publications

Comparative finite element analysis: internal fixation plate versus intramedullary nail for neer type III-VI proximal humeral fractur.

J Orthop Surg Res

January 2025

Department of Orthopedics, Beijing Chaoyang Hospital, Capital Medical University, 8 Gongren Tiyuchang Nanlu, Chaoyang District, Beijing, 100020, China.

Background: Finite element analysis (FEA) could advance the understanding of fracture fixation and guide the choice of surgical treatment. This study aimed to compare two internal fixation methods in the treatment of displaced proximal humeral fracture (PHF) through FEA.

Methods: Three-dimensional FEA model based on the left shoulder joint of a 67-year-old female patient with PHFs and osteoporosis was adopted, in order to analyze the fixation effect and load stress distribution of internal fixation plates with open reduction and intramedullary nails without opening the fracture in the treatment of Neer III-VI PHF.

View Article and Find Full Text PDF

A non-metallic PEEK topology optimization reconstruction implant for large mandibular continuity defects, validated using the MANDYBILATOR apparatus.

Sci Rep

January 2025

Department of Oral and Maxillofacial Surgery, University Medical Center Groningen, University of Groningen, Hanzeplein 1, P.O. Box 30.001, 9700 RB, Groningen, The Netherlands.

In cases of large mandibular continuity defects resulting from malignancy resection, the current standard of care involves using patient-specific/custom titanium reconstruction plates along with autogenous grafts (fibula, scapula, or iliac crest segments). However, when grafts are not feasible or desired, only the reconstruction plate is used to bridge the gap. Unfortunately, metal osteosynthesis and reconstruction plates, including titanium, exhibit adverse effects such as stress-shielding and limitations in accurate postoperative irradiation (especially with proton-beam therapy).

View Article and Find Full Text PDF

The main advantages of microneedles are precise drug delivery through human skin, minimal tissue damage and painlessness. We conducted structural analysis and skin puncture studies of hollow microneedles using ANSYS for three materials: Hafnium Dioxide (HfO), Polyglycolic acid (PGA) and Polylactic acid (PLA). Firstly, we selected three lengths, three tip diameters and three base diameters to conduct a L(3) orthogonal experiment.

View Article and Find Full Text PDF

Experimental investigation and finite element analysis on the durability of root-filled teeth treated with multisonic irrigation.

Dent Mater

January 2025

Minnesota Dental Research Center for Biomaterials and Biomechanics, School of Dentistry, University of Minnesota, Minneapolis, MN, USA. Electronic address:

Objective: This study compared the fracture load, stress distribution, and survival probability under cyclic loading of extensively restored teeth treated with multisonic irrigation with those treated with conventional instrumentation, with or without a post.

Methods: Mesial-occlusal-distal cavities were prepared in 30 human mandibular premolars. The teeth were randomly divided into 3 groups of 10 based on the endodontic and restorative procedures: (1) Root canal treatment (RCT) followed by resin composite restoration (control group), (2) RCT followed by a glass fiber post restoration (conventional group), and (3) minimal instrumentation plus multisonic irrigation followed by resin composite restoration (GW group).

View Article and Find Full Text PDF

Objective: Photopolymerized resin composites are widely used as dental filling materials. However, the shrinkage stress generated during photopolymerization can lead to marginal microcracks and eventual restoration failure. Accurate assessment of the stress evolution in dental restorations, particularly in complex cavity geometries, is critical for improving the performance and longevity of the dental filling materials.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!