Background Smartphone technology is rapidly evolving and advancing, with many of them offering health applications being used for oximetry purposes, including the Samsung Health/S Health application. Measuring oxygen saturation is one of the important indications to monitor patients with COVID-19, as well as other health conditions. These applications can be used for measuring oxygen saturation to provide a convenient solution for clinical decisions. Methods Oxygen saturation measurements were collected using the Samsung Health application for Samsung Galaxy smartphone with a sensor and camera flash and a low-cost portable digital display (liquid crystal display (LCD)) finger pulse oximeter. Intra-session reliability was established to determine the consistency between the measures. Intra-class correlation coefficients (ICCs) were calculated with 95% confidence intervals (CIs) reported for both methods. The Bland-Altman plot was used to compare the level of agreement between the two measurement methods. Results There was a statistically significant average difference between pulse oximeter and Samsung Health application measurements (t = 4.407, p < 0.001), and on average, pulse oximeter measurement was 0.510 points higher than Samsung Health application measurement (95% CI = 0.281-0.740). The pulse oximeter and Samsung Health application scores were moderately correlated (r = 0.462). The results of the intra-session reliability test produced an acceptable ICC value of 0.557, indicating moderate reliability and consistent results for the measurement of oxygen saturation with both methods. The Bland-Altman plot showed a consistently equal distribution of data points scattered above and below zero. Conclusion Smartphone health applications can be used with moderate reliability to measure oxygen saturation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8654113PMC
http://dx.doi.org/10.7759/cureus.19417DOI Listing

Publication Analysis

Top Keywords

oxygen saturation
24
health application
20
samsung health
16
pulse oximeter
16
health
8
health applications
8
measuring oxygen
8
intra-session reliability
8
methods bland-altman
8
bland-altman plot
8

Similar Publications

Background: Atrial septal defects (ASDs) are a common cause of congenital heart disease worldwide.

Objectives: The purpose of the study was to assess change over time in surgical outcomes for ASD repair and identify patient-level risk factors for adverse postoperative outcomes.

Methods: We analyzed cases of isolated ASD in patients <18 years from 2010 to 2020 from 71 sites participating in the International Quality Improvement Collaborative for Congenital Heart Disease.

View Article and Find Full Text PDF

Radiation therapy (RT) is widely used for cancer treatment but is found with side effects of radiation dermatitis and fibrosis thereby calling for timely assessment. Nevertheless, current clinical assessment methods are found to be subjective, prone to bias, and accompanied by variability. There is, therefore, an unmet clinical need to explore a new assessment technique, ideally portable and affordable, making it accessible to less developed regions too.

View Article and Find Full Text PDF

Background: As iatrogenic hyperoxia has been related to adverse outcomes in critically ill patients, guidelines advise to titrate oxygen to physiological levels. In the prehospital setting where partial arterial oxygen (PaO) values are often not readily available, titration of oxygen is based on peripheral oxygen saturations (SpO2). In this study we aimed to investigate the efficacy of SpO guided oxygen titration in the prevention of hyperoxia.

View Article and Find Full Text PDF

Remote monitoring of patients with COPD disease using a tablet system: a randomised crossover study of quality-of-life measurements.

ERJ Open Res

January 2025

Department of Respiratory Medicine and Allergology, COPD Center, Sahlgrenska University Hospital and Department of Internal Medicine and Clinical Nutrition, Institute of Medicine, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.

Background: Remote patient monitoring (RPM) has been evaluated in COPD, but with varying results. We aimed to evaluate whether a tablet system that monitors disease-related parameters in patients with COPD could influence physical and mental health-related quality of life, compared with usual care (UC).

Methods: 70 patients with Global Initiative for Chronic Obstructive Lung Disease (GOLD) group D COPD (61% women, aged 71±8 years, forced expiratory volume in 1 s % predicted 41±13%, COPD Assessment Test (CAT) 19±7 points) were recruited at the COPD centre in Gothenburg, Sweden, and randomised to a tablet-based RPM system or UC for a 26-week period, after which they crossed over to the alternative management for another 26 weeks.

View Article and Find Full Text PDF

Purpose: The effect of metabolic factors on cardiovascular risk in obstructive sleep apnea (OSA) is unclear. This study aimed to investigate the effect of metabolic factors on the left ventricular diastolic function in patients with OSA.

Patients And Methods: This cross-sectional study included a total of 478 patients with OSA from September 2018 to September 2023.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!