This study aimed to investigate the clinical efficacy of robot-assisted neuroendoscopic hematoma evacuation combined intracranial pressure (ICP) monitoring for the treatment of hypertensive intracerebral hemorrhage (HICH). A retrospective analysis of 53 patients with HICH undergoing neuroendoscopic hematoma evacuation in our department from January 2016 to December 2020 was performed. We divided the patients into two groups: the neuroendoscopic group ( = 32) and the robot-assisted neuroendoscopic combined ICP monitoring group ( = 21). Data on clinical characteristics, treatment effects, and outcomes were retrospectively reviewed and analyzed between these two groups. The operation time of the procedure of the neuroendoscopic group was significantly longer than that of the robot-assisted neuroendoscopic combined ICP-monitoring group (mean time 153.8 ± 16.8 vs. 132.8 ± 15.7 min, < 0.001). The intraoperative blood loss was significantly less in the robot-assisted neuroendoscopic combined ICP-monitoring group than in the neuroendoscopic group (215.4 ± 28.3 vs. 190.1 ± 25.6 ml, = 0.001). However, the patients undergoing neuroendoscopic had a comparable hematoma clearance rate with those undergoing robot-assisted neuroendoscopic combined ICP monitoring (85.2 ± 4.8 vs. 89.2 ± 5.4%, = 0.997). The complications rate was greater in the endoscopic group (25%) than in the robot-assisted neuroendoscopic combined ICP-monitoring group (9.5%) but without significant difference ( = 0.159). We also found that the dose of used mannitol was significantly less in the ICP monitoring group (615.2 ± 63.8 vs. 547.8 ± 65.3 ml, < 0.001) and there was a significant difference in modified Rankin scale (mRS) score at discharge, patients with less mRS score in the robot-assisted neuroendoscopic combined ICP monitoring group than in the neuroendoscopic group (3.0 ± 1.0 vs. 3.8 ± 0.8, = 0.011). Patients undergoing robot-assisted neuroendoscopic combined ICP monitoring had better 6-month functional outcomes, and there was a significant difference between the two groups ( = 0.004). Besides, multivariable analysis shows younger age, no complication, and robot-assisted neuroendoscopic combined ICP monitoring were predictors of 6-month favorable outcomes for the patients with HICH. Robot-assisted neuroendoscopic hematoma evacuation combined with ICP monitoring appears to be safer and more effective as compared to the neuroendoscopic hematoma evacuation in the treatment of HICH. Robot-assisted neuroendoscopic hematoma evacuation combined with ICP monitoring might improve the clinical effect and treatment outcomes of the patients with HICH.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8674426PMC
http://dx.doi.org/10.3389/fneur.2021.722924DOI Listing

Publication Analysis

Top Keywords

robot-assisted neuroendoscopic
48
icp monitoring
36
neuroendoscopic combined
32
combined icp
28
neuroendoscopic hematoma
24
hematoma evacuation
24
neuroendoscopic
18
evacuation combined
16
neuroendoscopic group
16
robot-assisted
12

Similar Publications

Hypertensive intracerebral hemorrhage (HICH), particularly affecting the basal ganglia, is a devastating condition with high mortality and morbidity rates. Traditional management, primarily conservative or invasive craniotomy, often leads to poor outcomes. This study highlights the potential of robot-assisted drainage as a superior treatment option for minor basal ganglia hemorrhage.

View Article and Find Full Text PDF

Background: To investigate the long-term follow-up and economic estimation outcomes of hematoma drainage for spontaneous intracerebral hemorrhage (SICH) with the assistance of neurosurgical navigation and positioning planning system (referred to as robot).

Methods: Data were retrospectively obtained from consecutive patients with SICH who were admitted to our single-center between March 2019 and March 2022. Different minimally invasive surgery (MIS) procedures were performed according to the inclusion/exclusion criteria.

View Article and Find Full Text PDF

Pre-Clinical Development of Robot-Assisted Ventriculoscopy for 3D Image Reconstruction and Guidance of Deep Brain Neurosurgery.

IEEE Trans Med Robot Bionics

February 2022

Department of Biomedical Engineering and Department of Computer Science, Johns Hopkins University, Baltimore, MD, USA.

Conventional neuro-navigation can be challenged in targeting deep brain structures via transventricular neuroendoscopy due to unresolved geometric error following soft-tissue deformation. Current robot-assisted endoscopy techniques are fairly limited, primarily serving to planned trajectories and provide a stable scope holder. We report the implementation of a robot-assisted ventriculoscopy (RAV) system for 3D reconstruction, registration, and augmentation of the neuroendoscopic scene with intraoperative imaging, enabling guidance even in the presence of tissue deformation and providing visualization of structures beyond the endoscopic field-of-view.

View Article and Find Full Text PDF

This study aimed to investigate the clinical efficacy of robot-assisted neuroendoscopic hematoma evacuation combined intracranial pressure (ICP) monitoring for the treatment of hypertensive intracerebral hemorrhage (HICH). A retrospective analysis of 53 patients with HICH undergoing neuroendoscopic hematoma evacuation in our department from January 2016 to December 2020 was performed. We divided the patients into two groups: the neuroendoscopic group ( = 32) and the robot-assisted neuroendoscopic combined ICP monitoring group ( = 21).

View Article and Find Full Text PDF

The widespread application of endoscopic ear surgery (EES), performed through the external auditory canal, has revealed the limitations of the one-handed technique. The RobOtol® (Collin ORL, Bagneux, France) otological robotic system has been introduced to enable two-handed procedures; however, the thermal properties of dedicated endoscopes, which are usually used in neurosurgery, called "neuro-endoscopes," have not yet been clarified for the robotic systems. In this study, we aimed to profile the thermal characteristics of two dedicated neuro-endoscopes, as compared to endoscopes used routinely in manual EES, called "oto-endoscopes," and defined by a smaller diameter and shorter length, and to discuss the safe application of robotic assistance in EES.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!