Purpose: To assess the repeatability of corneal dynamic response (CDR) parameters in normal and keratoconus (KC) eyes using ultra high-speed Scheimpflug imaging.
Methods: Prospective, comparative, observational study, including eyes of 112 patients that underwent high-speed Scheimpflug imaging analysis (Corvis ST, OCULUS). Twenty-one CDR parameters were evaluated to asses repeatability using: coefficient of repeatability (CR), coefficient of variation, intraclass correlation coefficient (ICC) and within-subject SD. Three consecutive measurements by the same operator were performed for each eye.
Results: There were no significant differences between the three consecutive measurements for all parameters in both normal and KC eyes. 71.42% (15 of the 21 parameters evaluated) and 85.71% (18 of the 21 parameters) were highly repeatable in the normal and KC group, respectively. The tomographic biomechanical index (TBI), corneal biomechanical index (CBI), and stiffness parameter (SPA1) showed an ICC of 0.978, 0.954, and 0.958 in normal and 0.982, 0.892, and 0.978 in KC eyes, respectively. The CR in normal eyes for TBI, CBI, and SPA1 were 0.169, 0.242, and 14.12, respectively, and for KC eyes 0.06, 0.23, and 13.64, respectively.
Conclusions: Most of the corneal dynamic response parameters were highly repeatable in normal and KC eyes.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/ICL.0000000000000845 | DOI Listing |
Unlabelled: The introduction of bidirectional corneal applanation technologies into clinical practice made possible the in vivo assessment of biomechanical properties of the fibrous tunic in myopic eyes.
Purpose: This study analyzes the potential of bidirectional corneal applanation with high-speed video recording for biomechanical control of myopia, focusing on the biomechanical parameters of the sclera and cornea.
Material And Methods: The study included 129 patients (168 eyes) with myopia ranging from -0.
Front Neurosci
May 2024
Department of Ophthalmology, Peking University Third Hospital, Beijing, China.
Purpose: To explore the influence of corneal higher-order aberrations (HOAs) on dynamic visual acuity (DVA) post cataract surgery.
Methods: A total of 27 patients with 45 eyes following cataract surgery were included in this study. The postoperative monocular object-moving DVA at the velocity of 20, 40, and 80 degrees per second (dps) were examined at 1 month.
Biomed Eng Online
January 2024
School of Medicine, Nankai University, Tianjin, China.
Background: In this study, an automatic corneal contour extraction algorithm with a shared model is developed to extract contours from dynamic corneal videos containing noise, which improves the accuracy of corneal biomechanical evaluation and clinical diagnoses. The algorithm does not require manual labeling and completes the unsupervised semantic segmentation of each frame in corneal dynamic deformation videos based on a fully convolutional deep-learning network using corneal geometry and texture information.
Results: We included 1027 corneal videos at Tianjin Eye Hospital (Nankai University Affiliated Eye Hospital) from May 2020 to November 2021.
Sci Rep
October 2023
Department of Ophthalmology, University of São Paulo, São Paulo, Brazil.
This study aimed to investigate the effects of topical anesthetic and fluorescein drops on intraocular pressure (IOP), central corneal thickness (CCT) and biomechanical properties as measured by Corvis ST (CST-Oculus; Wezlar, Germany) in healthy eyes. A cross-sectional observational study was conducted on 46 healthy patients. The CST measurements were obtained before and immediately after the instillation of topical anesthetic and fluorescein drops.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!