Performing phacoemulsification in eyes with corneal opacities is challenging even with expert surgeons. Several techniques have been described to improve intraoperative visualization through opacified corneas. This retrospective interventional case series included 10 eyes of 10 patients with coexisting senile cataract and corneal opacity who underwent phacoemulsification with intraocular lens (IOL) implantation under slit illumination of the surgical microscope. Uneventful phacoemulsification with IOL implantation was achieved in all eyes without intraoperative complications. Slit illumination reduced the light scattering and reflection from the corneal opacity, enhanced the red reflex, and improved depth perception simultaneously in different steps of phacoemulsification. Phacoemulsification was safely performed in eyes with corneal opacity under slit illumination of the surgical microscope. It can be considered as a viable option for improving intraoperative visualization in patients with corneal opacities without additional instrumentation.

Download full-text PDF

Source
http://dx.doi.org/10.1097/j.jcrs.0000000000000877DOI Listing

Publication Analysis

Top Keywords

slit illumination
16
corneal opacities
12
illumination surgical
12
surgical microscope
12
corneal opacity
12
patients corneal
8
eyes corneal
8
intraoperative visualization
8
iol implantation
8
phacoemulsification
6

Similar Publications

The Role of Podocytes in Lupus Pathology.

Curr Rheumatol Rep

December 2024

Department of Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, 330 Brookline Avenue, CLS-937, Boston, MA, 02215, USA.

Purpose Of Review: Kidney injury due to lupus nephritis (LN) is a severe and sometimes life-threatening sequela of systemic lupus erythematosus. Autoimmune injury to podocytes has been increasingly demonstrated to be a key driver of LN-related kidney injury because these cells play key roles in glomerular filtration barrier homeostasis. Irreparable podocyte injury impairs these processes and can lead to proteinuria, which is an indicator of poor prognosis in LN.

View Article and Find Full Text PDF

Purpose: To assess the safety and the efficacy of the "Sub-400 corneal cross-linking (CXL) protocol" for progressive keratoconus (KC) in ultrathin corneas.

Methods: The study included thirty four patients with progressive KC, who underwent CXL using the "Sub-400" protocol due to intraoperative thinnest corneal pachymetry ranging from 295 to 398 μm after epithelial removal. After the epithelium was removed, the following ultraviolet A irradiation was applied at a fluence of 3 mW/cm and the duration was adjusted based on the specific corneal stromal thickness.

View Article and Find Full Text PDF

We developed a compact wide-range light source system for evaluating the linearity of photomultiplier tube (PMT) output. This system utilizes two integrating spheres equipped with a continuously variable slit and output aperture to modulate a stabilized light-emitting diode light source, producing an output light range as wide as seven orders of magnitude. To verify the wide linearity range of the integrating sphere system, three silicon photodiodes coupled with electric current readers monitored the light intensity and simultaneously confirmed each other's linearity.

View Article and Find Full Text PDF

Introduction: Idiopathic congenital acorea is extremely rare. There are several techniques for preserving the clear lens during pupil formation.

Case Presentation: The complete pupil absence caused acute glaucoma attack 2 weeks after birth, which was controlled in a 1-month-old child by peripheral iridectomy and disconnecting iris-corneal synechias.

View Article and Find Full Text PDF
Article Synopsis
  • Surface plasmon polaritons (SPPs) are important in sensitive biomolecular detection and optical communication technologies, but their interaction with other near-field modes like quasi-cylindrical waves (QCWs) and composite diffracted evanescent waves (CDEWs) is not fully understood.
  • This study utilized a nano groove structure and a stable femtosecond laser to measure the spatial phase distribution around the edge of a nano slit, achieving a high precision measurement of refractive index changes.
  • The findings provide insights into the near-field effects on electron concentration at the nano structures, enhancing the understanding of SPP phenomena which could improve the design and application of nano-plasmonic technologies.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!