Background: Cardiovascular implantable electronic device (CIED) implantation has markedly increased over the past 2 decades. Staphylococcus aureus bacteremia (SAB) occurs in patients with CIED, and determination of device infection often is difficult.

Objectives: The purpose of this study was to examine the rate and clinical characteristics of SAB in patients living with CIED using the 2019 European Heart Rhythm Association (EHRA) international consensus document.

Methods: We conducted a retrospective study of patients with CIED who were hospitalized at Mayo Clinic, Rochester, with SAB from 2012 to 2019. Patients who met CIED infection criteria after SAB based on EHRA criteria were identified. A descriptive statistic and time-dependent Cox model were used.

Results: Overall, 110 patients with CIED developed SAB, of whom 92 (83.6%) underwent transesophageal echocardiogram (TEE). Fifty-seven (51.8%) and 31 (28.2%) patients met criteria for definite and possible CIED infections, respectively. At 30-day follow-up, the cumulative rate of patients undergoing complete device extraction was 80.0% in the definite CIED infection group, compared with 38.8% and 32.9% in the possible and rejected CIED infection groups, respectively. We found that CIED extraction was associated with an 83% reduction in risk of 1-year mortality in the definite CIED infection group.

Conclusion: The rate of CIED infections after SAB was higher than that reported previously. Increased use of TEE and a novel case definition with broader diagnostic criteria likely were operative, in part, in accounting for the higher rate of CIED infections complicating SAB. Complete device removal is critical in patients with definite CIED infection to improve 1-year mortality.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.hrthm.2021.12.013DOI Listing

Publication Analysis

Top Keywords

cied infection
20
definite cied
16
cied
14
patients cied
12
cied infections
12
patients
9
european heart
8
heart rhythm
8
rhythm association
8
cardiovascular implantable
8

Similar Publications

This case details the successful implantation of a leadless pacemaker following the extraction of transvenous leads in a 72-year-old female patient with a complex cardiovascular history. The patient had undergone a series of cardiac interventions, including a recent percutaneous tricuspid valve repair with a metal clip implant due to severe regurgitation. After presenting with an infection at the pacemaker site, methicillin-resistant Staphylococcus hominis was identified, necessitating the removal of the entire pacing system.

View Article and Find Full Text PDF

Background: Globally, the number of cardiac implantable electronic devices (CIEDs) is increasing. In our study, we aimed to investigate whether CHADS-VASc and RCHADS-VASc scores are predictive of CIED-related complications.

Methods: Our investigation was carried out with a multicenter retrospective design.

View Article and Find Full Text PDF

Background: Removal of cardiac implantable electronic devices (CIEDs) is strongly recommended for CIED-related infections, and leadless pacemakers (LPs) are increasingly used for reimplantation. However, the optimal timing and safety of LP implantation after CIED removal for infection remains unclear.This systematic review and meta-analysis aimed to assess complication rates (all-cause mortality and reinfection) when LP implantation was performed simultaneously with or after CIED removal.

View Article and Find Full Text PDF

Fat Liquefaction and Lipo Particles in a CIED Pocket During Generator Change-Not an Infection: A Rare Case Report.

Int Med Case Rep J

January 2025

Department of Cardiology, Heart Center, Qingdao Municipal Hospital, Qingdao, Shandong, 266071, People's Republic of China.

A case of fat liquefaction and fat particles in the pacemaker pocket observed in a female patient 12 years after implantation. The patient had no symptoms and no signs of infection or other discomfort of the heart and pacemaker pocket. The biochemical analysis showed a slight increase in cardiac troponin T, 0.

View Article and Find Full Text PDF

Cardiac implantable electronic devices (CIEDs), including pacemakers, implantable cardiac defibrillators (ICD), and cardiac resynchronization therapy (CRT) devices, regulate heart rate and rhythm in patients with cardiac conditions. With an aging population, CIED-related complications, especially pacemaker pocket infections, are rising. Risk factors include frailty, older age, and superficial device fixation, while risk mitigation involves larger pocket sizes, submuscular fixation, and absorbable antibacterial envelopes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!