Digital radiographs are common for estimating bone mineral content (BMC) in horses with radiographic bone aluminum equivalents (RBAE). Processing algorithms are used to produce clearer images of digital radiographs in clinical settings, but this distorts RBAE. This study compared RBAE from digital radiographs to BMC from bone ash, and physical and digital morphology measurements. Digital radiographs were taken of six third metacarpals (MCIII) from equine cadavers with an aluminum step wedge penetrometer. A 2-cm transverse section of bone was digitally analyzed and excised from each MCIII. For each image, a linear regression was created using the step wedge thicknesses (R > 0.99) and used to obtain total and individual RBAE. Outer and inner diameters of both dorsal-palmar (DP) and lateral-medial (LM) aspects, as well as cortical thicknesses, were measured physically and digitally. Bone samples were ether-extracted, oven-dried, and ashed. Statistics were analyzed as correlations between variables. Physical and digital measurements of dorsal, medial, and lateral cortices, as well as DP outer diameter, tended to be similar (r > 0.74, P < .09) but palmar cortex measurements did not (r = 0.41, P = .42). The LM outer and DP/LM inner diameters were similar between the two methods (r > 0.95, P < .05). Total RBAE was strongly correlated to BMC (r > 0.93, P < .01). These results suggest that using digital radiographs to make morphological measurements is accurate and confirm the strong relationship between total RBAE and bone ash. However, this study emphasizes the need to use unprocessed radiographs for analysis.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jevs.2021.103837DOI Listing

Publication Analysis

Top Keywords

digital radiographs
24
bone mineral
8
mineral content
8
radiographic bone
8
bone aluminum
8
aluminum equivalents
8
digital
8
bone ash
8
physical digital
8
step wedge
8

Similar Publications

Purpose: Achieving precise postoperative alignment is critical for the long-term success of total knee arthroplasty (TKA). Long-leg standing radiograph (LLR) at 6 weeks post-op is the gold standard for assessing alignment, but its reliance on weight-bearing and positioning makes it less practical in the early postoperative period. Supine computed tomography scanogram (CTS) offers a potential alternative.

View Article and Find Full Text PDF

We developed a simple quantifiable scoring system that predicts aneurysmal subarachnoid hemorrhage (aSAH) mortality, delayed cerebral ischemia (DCI), and modified Rankin scale (mRS) outcomes using readily available SAH admission data with SAH volume (SAHV) measured on computed tomography (CT). We retrospectively analyzed a cohort of 277 patients with aSAH admitted at our Comprehensive Stroke Center at Mayo Clinic in Jacksonville, Florida, between January 5, 2012, and February 24, 2022. We developed a mathematical radiographic model SAHV that measures basal cisternal SAH blood volume using a derivation of the ABC/2 ellipsoid formula (A = width/thickness, B = length, C = vertical extension) on noncontrast CT, which we previously demonstrated is comparable to pixel-based manual segmentation on noncontrast CT.

View Article and Find Full Text PDF

A spontaneous pneumothorax may be the heralding manifestation of diffuse cystic lung disease (DCLD). Historically, these diagnoses were differentiated by unique clinical, radiographic and tissue pathology characteristics. With recent advancements in genomics, several forms of DCLD can now be diagnosed through genetic testing and patients can thereby avoid undergoing an invasive lung biopsy.

View Article and Find Full Text PDF

Simulated low-dose dark-field radiography for detection of COVID-19 pneumonia.

PLoS One

December 2024

Chair of Biomedical Physics, Department of Physics & School of Natural Sciences, Technical University of Munich, Garching bei München, Germany.

Background: Dark-field radiography has been proven to be a promising tool for the assessment of various lung diseases.

Purpose: To evaluate the potential of dose reduction in dark-field chest radiography for the detection of the Coronavirus SARS-CoV-2 (COVID-19) pneumonia.

Materials And Methods: Patients aged at least 18 years with a medically indicated chest computed tomography scan (CT scan) were screened for participation in a prospective study between October 2018 and December 2020.

View Article and Find Full Text PDF

Optimizing dual energy X-ray image enhancement using a novel hybrid fusion method.

J Xray Sci Technol

December 2024

School of Electrical and Information Engineering, Tianjin University, Nankai District, Tianjin, China.

Background: Airport security is still a main concern for assuring passenger safety and stopping illegal activity. Dual-energy X-ray Imaging (DEXI) is one of the most important technologies for detecting hidden items in passenger luggage. However, noise in DEXI images, arising from various sources such as electronic interference and fluctuations in X-ray intensity, can compromise the effectiveness of object identification.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!