Background: Elderly patients are a growing population in cardiac rehabilitation (CR). As postural control declines with age, assessment of impaired balance is important in older CR patients in order to predict fall risk and to initiate counteracting steps. Functional balance tests are subjective and lack adequate sensitivity to small differences, and are further subject to ceiling effects. A quantitative approach to measure postural control on a continuous scale is therefore desirable. Force plates are already used for this purpose in other clinical contexts, therefore could be a promising tool also for older CR patients. However, in this population the reliability of the assessment is not fully known.
Research Question: Analysis of test-retest reliability of center of pressure (CoP) measures for the assessment of postural control using a force plate in older CR patients.
Methods: 156 CR patients (≥75 years) were enrolled. CoP measures (path length (PL), mean velocity (MV), and 95% confidence ellipse area (95CEA)) were analyzed twice with an interval of two days in between (bipedal narrow stance, eyes open (EO) and closed (EC), three trials for each condition, 30 s per trial), using a force plate. For test-retest reliability estimation absolute differences (Δ: T0-T1), intraclass correlation coefficients (ICC) with 95% confidence intervals, standard error of measurement and minimal detectable change were calculated.
Results: Under EO condition ICC were excellent for PL and MV (0.95) and good for 95CEA (0.88) with Δ of 10.1 cm (PL), 0.3 cm/sec (MV) and 1.5 cm (95CEA) respectively. Under EC condition ICC were excellent (≥ 0.95) for all variables with larger Δ (PL: 21.7 cm; MV: 0.7 cm/sec; 95CEA: 2.4 cm).
Significance: In older CR patients, the assessment of CoP measures using a force plate shows good to excellent test-retest reliability.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.gaitpost.2021.12.011 | DOI Listing |
MAGMA
January 2025
Medical Physics Group, Institute of Diagnostic and Interventional Radiology, Jena University Hospital, Friedrich Schiller University Jena, Jena, Germany.
Objective: To establish an arterial spin labeling (ASL) protocol for rat livers that improves data reliability and reproducibility for perfusion quantification.
Methods: This study used respiratory-gated, single-slice, FAIR-based ASL imaging with multiple inversion times (TI) in rat livers. Quality assurance measures included: (1) introduction of mechanical ventilation to ensure consistent respiratory cycles by controlling the respiratory rate (45 bpm), tidal volume (10 ml/kg), and inspiration: expiration ratio (I:E ratio, 1:2), (2) optimization of the trigger window for consistent trigger points, and (3) use of fit residual map and coefficient of variance as metrics to assess data quality.
Am J Sports Med
January 2025
Department of Orthopedics and Rehabilitation, Tufts Medical Center, Boston, Massachusetts, USA.
Background: The Minimum Information for Studies Evaluating Biologics in Orthopedics (MIBO) guidelines were developed in May 2017 to encourage improved reporting standards, promote increased transparency and reproducibility, and enhance clinical evaluation capabilities. The MIBO guidelines consist of 23 checklist items considered necessary to critically appraise clinical studies evaluating platelet-rich plasma (PRP).
Purpose: To assess randomized controlled trials that evaluated PRP for the treatment of knee osteoarthritis in order to systematically review their adherence to the MIBO guidelines.
Sci Data
January 2025
Lab for Autonomic Neuroscience, Imaging and Cognition (LANIC), Department of Psychosomatic Medicine and Psychotherapy, Jena University Hospital, Jena, Germany.
Heart rate variability (HRV) is a key indicator of cardiac autonomic function, making reliable assessment crucial. To examine the test-retest stability of resting HRV in healthy individuals, fifty participants attended two lab sessions within a week, at the same time of day. After a 5-minute acclimatization period, electrocardiogram and respiration were recorded at rest.
View Article and Find Full Text PDFScand J Med Sci Sports
January 2025
Department of Sports Science and Clinical Biomechanics, University of Southern Denmark, Odense, Denmark.
Reliable and sensitive testing of physical function is crucial for assessing the effects of treatment or exercise intervention in various patient populations. The present study investigated the test-retest reliability and sensitivity (smallest detectable difference: SDD) of selected physical performance tests commonly used in clinical rehabilitation, including tests of habitual and maximal walking speed, walking endurance capacity, handgrip strength (HGS), and lower limb muscle power (Sit-to-Stand (STS), stair climb) in adults with severe obesity meeting the criteria for bariatric surgery. Thirty-two adults (BMI 43.
View Article and Find Full Text PDFSci Rep
January 2025
Department of urinary surgery, Henan Provincial People's Hospital, Zhengzhou University People's Hospital, Zhengzhou, 450003, Henan, China.
Alexithymia, a cognitive and emotional deficit characterized by difficulty in expressing emotions and identifying feelings, poses significant challenges in healthcare settings. Developing a reliable and valid tool to measure alexithymia in post-prostatectomy patients would not only aid healthcare professionals in identifying at-risk individuals but also facilitate early intervention and targeted support. This study aimed to translate the Brief Form of the Normative Male Alexithymia Scale (NMAS-BF) into Simplified Chinese, evaluate the reliability and validity of the Chinese version, and explore its influencing factors.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!