Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: The NEMIS Technologies N-LightTM L. monocytogenes assay uses chemiluminescence designed for the qualitative detection of Listeria monocytogenes from environmental surface samples.
Objective: To validate the NEMIS Technologies N-Light L. monocytogenes assay as part of the AOAC Performance Tested MethodSM program for the detection of L. monocytogenes on stainless steel, plastic (polystyrene), and ceramic environmental surfaces.
Method: Using the Vitl Life Science Solutions Lu-mini luminometer, the NEMIS Technologies N-Light L. monocytogenes assay was compared to the ISO 11290-1:2017: Microbiology of the Food Chain-Horizontal method for the detection and enumeration of Listeria monocytogenes and of Listeria spp. - Part 1 using a 1" × 1" stainless steel test area in an unpaired study design.
Results: The NEMIS Technologies N-Light L. monocytogenes assay using the Vitl Life Science Solutions Lu-mini luminometer demonstrated no statistically significant differences between presumptive and confirmed results or between candidate and reference method results. Data for additional Performance Tested MethodSM studies met acceptance criteria requirements.
Conclusions: The NEMIS Technologies N-Light L. monocytogenes assay is an effective method for the qualitative detection of L. monocytogenes from stainless steel, plastic (polystyrene), and ceramic environmental surface samples.
Highlights: The NEMIS method is the first chemiluminescence detection system based on a novel, patented, dioxetane compound.