Cross-Cohort Automatic Knee MRI Segmentation With Multi-Planar U-Nets.

J Magn Reson Imaging

Department of Computer Science, University of Copenhagen, Copenhagen, Denmark.

Published: June 2022

Background: Segmentation of medical image volumes is a time-consuming manual task. Automatic tools are often tailored toward specific patient cohorts, and it is unclear how they behave in other clinical settings.

Purpose: To evaluate the performance of the open-source Multi-Planar U-Net (MPUnet), the validated Knee Imaging Quantification (KIQ) framework, and a state-of-the-art two-dimensional (2D) U-Net architecture on three clinical cohorts without extensive adaptation of the algorithms.

Study Type: Retrospective cohort study.

Subjects: A total of 253 subjects (146 females, 107 males, ages 57 ± 12 years) from three knee osteoarthritis (OA) studies (Center for Clinical and Basic Research [CCBR], Osteoarthritis Initiative [OAI], and Prevention of OA in Overweight Females [PROOF]) with varying demographics and OA severity (64/37/24/53/2 scans of Kellgren and Lawrence [KL] grades 0-4).

Field Strength/sequence: 0.18 T, 1.0 T/1.5 T, and 3 T sagittal three-dimensional fast-spin echo T1w and dual-echo steady-state sequences.

Assessment: All models were fit without tuning to knee magnetic resonance imaging (MRI) scans with manual segmentations from three clinical cohorts. All models were evaluated across KL grades.

Statistical Tests: Segmentation performance differences as measured by Dice coefficients were tested with paired, two-sided Wilcoxon signed-rank statistics with significance threshold α = 0.05.

Results: The MPUnet performed superior or equal to KIQ and 2D U-Net on all compartments across three cohorts. Mean Dice overlap was significantly higher for MPUnet compared to KIQ and U-Net on CCBR ( vs. and ), significantly higher than KIQ and U-Net OAI ( vs. and , and not significantly different from KIQ while significantly higher than 2D U-Net on PROOF ( vs. , , and . The MPUnet performed significantly better on KL grade 3 CCBR scans with vs. for KIQ and for 2D U-Net.

Data Conclusion: The MPUnet matched or exceeded the performance of state-of-the-art knee MRI segmentation models across cohorts of variable sequences and patient demographics. The MPUnet required no manual tuning making it both accurate and easy-to-use.

Level Of Evidence: 3 TECHNICAL EFFICACY: Stage 2.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9106804PMC
http://dx.doi.org/10.1002/jmri.27978DOI Listing

Publication Analysis

Top Keywords

kiq u-net
12
knee mri
8
mri segmentation
8
three clinical
8
clinical cohorts
8
mpunet performed
8
u-net
6
mpunet
6
kiq
6
knee
5

Similar Publications

Background: Segmentation of medical image volumes is a time-consuming manual task. Automatic tools are often tailored toward specific patient cohorts, and it is unclear how they behave in other clinical settings.

Purpose: To evaluate the performance of the open-source Multi-Planar U-Net (MPUnet), the validated Knee Imaging Quantification (KIQ) framework, and a state-of-the-art two-dimensional (2D) U-Net architecture on three clinical cohorts without extensive adaptation of the algorithms.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!