A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Testing of Novel Total Elbow Prostheses Using Active Motion Experimental Setup. | LitMetric

Purpose: The goal of this study was to test a novel uncemented and unconstrained total elbow arthroplasty (Kaufmann total elbow) design that is stabilized through a ligament reconstruction.

Methods: We quantified the implant stability after 25,000 cycles, which represents the time between implantation and when ligament and bone healing has occurred. We used an active motion experimental setup that applies tendon loads via pneumatic cylinders and reproduces the forearm-originating dynamic stabilizers of the elbow. The novel total elbow arthroplasty was actuated for 5,000 full flexion-extension cycles at 5 different shoulder positions. Four Sawbones and 4 cadaver elbows were employed. Angular laxity and implant stability were recorded prior to testing and after each 5,000-loading cycle.

Results: Four Sawbones and 4 cadaver elbows were implanted with the uncemented total elbow arthroplasty and did not demonstrate fixation failure or substantial laxity after 25,000 cycles of loading imparted at different shoulder positions.

Conclusions: Our findings demonstrate that the Kaufmann total elbow replacement implanted into cadaver and Sawbones specimens did not exhibit fixation failure or excessive laxity after 25,000 cycles.

Clinical Relevance: An uncemented, nonmechanically linked total elbow arthroplasty that gains component fixation using intramedullary screws and employs a ligament reconstruction to stabilize the elbow has the potential to be a valuable management option, particularly in younger patients.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jhsa.2021.10.020DOI Listing

Publication Analysis

Top Keywords

total elbow
28
elbow arthroplasty
16
elbow
9
novel total
8
active motion
8
motion experimental
8
experimental setup
8
kaufmann total
8
implant stability
8
25000 cycles
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!