Aims: We developed a catheter simulator for percutaneous transvenous mitral commissurotomy (PTMC) based on the data from a patient with mitral valve stenosis. The simulator has the following characteristics: 1) the simulator is portable and easy to assemble and disassemble, 2) the cardiac portion is created using a 3D-printer, based on patient computed tomography data, 3) the simulator uses a foot-operated water pump to create pulsatile flow, and 4) the fossa ovalis in the atrial septum of the heart model is made of a thin polyurethane membrane and is interchangeable. We aimed to assess the effectiveness of this novel simulator for training in PTMC using the Inoue balloon in developing countries.

Methods And Results: We used this simulator for training in the National Institute of Cardiovascular Diseases in Bangladesh (13 physicians), and in Kenyatta National Hospital in Kenya (11 physicians). The effectiveness of training was evaluated by questionnaire and the procedure time in simulation. The questionnaire obtained from the trainees showed that the model scored 4.7±0.5 for realism, utility of pulsatile flow scored 4.7±0.5, simulator utility scored 4.9±0.3, and the effect of training on PTMC performance scored 4.9±0.5. The procedure time in simulation was shortened from 30.0±12.6 min (first time), to 23.4±11.9 min (second time) and to 20.4 ± 11.1 min (third time) (p<0.01).

Conclusions: The novel portable assembly catheter simulator using a 3D-printed heart model for PTMC received positive comments and improved the skills of trainees.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8525714PMC
http://dx.doi.org/10.4244/AIJ-D-19-00013DOI Listing

Publication Analysis

Top Keywords

catheter simulator
12
simulator
9
heart model
8
percutaneous transvenous
8
transvenous mitral
8
mitral commissurotomy
8
pulsatile flow
8
simulator training
8
training ptmc
8
procedure time
8

Similar Publications

To investigate the feasibility of non-invasively estimating the arterial partial pressure of carbon dioxide (PaCO) using a computational Adaptive Neuro-Fuzzy Inference System (ANFIS) model fed by noninvasive volumetric capnography (VCap) parameters. In 14 lung-lavaged pigs, we continuously measured PaCO with an optical intravascular catheter and VCap on a breath-by-breath basis. Animals were mechanically ventilated with fixed settings and subjected to 0 to 22 cmHO of positive end-expiratory pressure steps.

View Article and Find Full Text PDF

Endovascular interventions are procedures designed to diagnose and treat vascular diseases, using catheters to navigate inside arteries and veins. Thanks to their minimal invasiveness, they offer many benefits, such as reduced pain and hospital stays, but also present many challenges for clinicians, as they require specialized training and heavy use of X-rays. This is particularly relevant when accessing (i.

View Article and Find Full Text PDF

Recapitulation of physiologic and pathophysiologic pulsatile CSF flow in purpose-built high-throughput hydrocephalus bioreactors.

Fluids Barriers CNS

December 2024

Department of Chemical Engineering and Materials Science, Wayne State University, 6135 Woodward Avenue, Rm 1413, Detroit, MI, 48202, USA.

Background: Hydrocephalus, an accumulation of cerebrospinal fluid (CSF) in the ventricles of the brain, is often treated via a shunt system to divert the excess CSF to a different compartment; if left untreated, it can lead to serious complications and permanent brain damage. It is estimated that one in every 500 people are born with hydrocephalus. Despite more than 60 years of concerted efforts, shunts still have the highest failure rate of any neurological device requiring follow-up shunt revision surgeries and contributing to the $2 billion cost of hydrocephalus care in the US alone.

View Article and Find Full Text PDF

The role of initial specimen diversion devices (ISDDs) in preventing contamination of central venous catheter (CVC) blood cultures is undefined. A model to simulate CVC colonization and contamination compared standard cultures with ISDD technique. ISDD detected 100% of colonized CVCs while decreasing false-positive cultures from 36% to 16%.

View Article and Find Full Text PDF

Background: Pulsed field ablation (PFA) has emerged as an effective technology in the treatment of paroxysmal atrial fibrillation (AF).

Objective: To evaluate the cost-effectiveness of PFA vs. thermal ablation from a US healthcare payer perspective using data from a randomized trial.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!