The dose conformity of carbon-ion beam radiotherapy, which allows the reduction of the dose deposition in healthy tissue and the escalation of the dose to the tumor, is associated with a high sensitivity to anatomical changes during and between treatment irradiations. Thus, the monitoring of inter-fractional anatomical changes is crucial to ensure the dose conformity, to potentially reduce the size of the safety margins around the tumor and ultimately to reduce the irradiation of healthy tissue. To do so, monitoring methods of carbon-ion radiotherapy in depth using secondary-ion tracking are being investigated. In this work, the detection and localization of a small air cavity of 2 mm thickness were investigated at different detection angles of the mini-tracker relative to the beam axis. The experiments were conducted with a PMMA head phantom at the Heidelberg Ion-Beam Therapy Center (HIT) in Germany. In a clinic-like irradiation of a single field of 3 Gy (RBE), secondary-ion emission profiles were measured by a 2 cm mini-tracker composed of two silicon pixel detectors. Two positions of the cavity in the head phantom were studied: in front and in the middle of the tumor volume. The significance of the cavity detection was found to be increased at smaller detection angles, while the accuracy of the cavity localization was improved at larger detection angles. Detection angles of 20° - 30° were found to be a good compromise for accessing both, the detectability and the position of the air cavity along the depth in the head of a patient.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8666547 | PMC |
http://dx.doi.org/10.3389/fonc.2021.780221 | DOI Listing |
J Colloid Interface Sci
January 2025
Institute of Physical and Theoretical Chemistry, University of Regensburg D-93053 Regensburg, Germany. Electronic address:
Hypothesis: Due to its huge polar headgroup, octaoxyethylene octyl ether carboxylic acid (CECHCOOH = Akypo LF2™) is supposed not to be able to change its curvature sufficiently to form bicontinuous microemulsions. Instead, upon adding an oil to the binary water - surfactant system, excess oil could be squeezed out or a biliquid foam could form.
Experiments: An auto-dilution setup was used to record small-angle X-ray scattering data along six dilution lines in the newly established phase diagram of the ternary system 2-ethylhexanol - CECHCOOH - water.
Anal Bioanal Chem
January 2025
Bio-analytical Laboratory, Shantou University Medical College, No. 22, Xinling Road, Shantou, 515041, China.
A polarimeter is a common but critical instrument for measuring the optical rotation of chiral compounds, ranging from the pharmaceutical to chemical industry, or even employed in monitoring chemical reactions for research purposes. Developing a portable polarimeter helps to transfer the measurements from the laboratory to on-site detection. Herein, we design a new portable polarimeter with a "hand-held" scale.
View Article and Find Full Text PDFJ Hand Surg Asian Pac Vol
January 2025
Ogori Daiichi General Hospital, Yamaguchi-ken, Japan.
In carpal tunnel syndrome (CTS), pain and sensory disturbance are the main symptoms, but thumb palmar abduction (TPA) paralysis cannot be ignored as a concurrent symptom. The reliable quantitative measurement of TPA power was not established. The purpose of this study was to report on the reliability of TPA strength measurements by the hand-held dynamometry (HHD) in large samples of CTS and its superiority over other tests, including grip, pinch powers, TPA angles and manual muscle testing, in terms of clinical progress indicators.
View Article and Find Full Text PDFExp Physiol
January 2025
Department of Clinical Medicine, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark.
There is limited knowledge on diffusing capacity in scoliosis patients. It remains to be determined if impaired pulmonary diffusing capacity is mostly influenced by reduced alveolar-capillary membrane diffusing capacity (D), reduced pulmonary capillary blood volume (V) or both. This study aims to report findings from dual test gas pulmonary diffusing capacity for carbon monoxide and nitric oxide (D) with quantification of pulmonary diffusing capacity for carbon monoxide corrected for haemoglobin with a five s breath-hold (D) and nitric oxide with a five s breath-hold (D), D and V.
View Article and Find Full Text PDFPlasmonic structured illumination microscopy (PSIM) is a super-resolution technique that utilizes surface plasmon polaritons (SPPs) with higher frequency as the structured light; thus, it is able to break the diffraction limit with a 3-4 times resolution enhancement. However, the low efficiency of near-field fluorescence collection results in a low imaging signal-to-noise ratio (SNR) of PSIM. In this paper, we propose a method to enhance the performance of PSIM with surface plasmon coupled emission (SPCE).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!