Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The purpose of this study was to compare the accuracy and the inter- and intra-observer reliability of preoperative digital 2D templating in prosthesis size prediction for the planning of cemented or uncemented THA.This study was registered in the NIHR PROSPERO database (ID: CRD42020216649) and conducted according to the PRISMA guidelines. A search of electronic databases in March 2021 found 29 papers overall. The quality of evidence was assessed using the IHE Quality Appraisal of Case Series Studies Checklist and the CASP Randomised Controlled Trials Checklist. A meta-analysis was conducted, and the accuracy was presented as proportions and the inter- and intra-observer reliability were measured using intraclass correlation coefficients (ICC).Accuracy within one prosthesis size (±1) for cemented stems was 0.89 (95% confidence interval (CI) 0.83-0.95), cemented cups 0.78 (95% CI 0.67-0.89), uncemented stems 0.74 (95% CI 0.66-0.82) and uncemented cups 0.73 (95% CI 0.67-0.79) (test of group differences: p = 0.010). Inter-observer reliability (ICC) for uncemented cups was 0.88 (95% CI 0.85-0.91), uncemented stems 0.86 (95% CI 0.81-0.91), cemented stems 0.69 (95% CI 0.54-0.84) and cemented cups 0.68 (95% CI 0.55-0.81) (test of group differences: p = 0.004). Due to lack of data, intra-observer reliability (ICC) could only be calculated for uncemented prostheses, which for the stems was 0.90 (95% CI 0.88-0.92) and for the cups was 0.87 (95% CI 0.83-0.90) (test of group differences: p = 0.124).The accuracy of preoperative digital templating is greater for cemented prostheses, but the inter-observer reliability is greater for uncemented prostheses. The intra-observer reliability showed a high level of agreement for uncemented prostheses. Cite this article: 2021;6:1020-1039. DOI: 10.1302/2058-5241.6.210048.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8631246 | PMC |
http://dx.doi.org/10.1302/2058-5241.6.210048 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!