Polyetheretherketone (PEEK) is widely used in orthopedic and craniomaxillofacial surgeries as it exhibits excellent biocompatibility, mechanical property, and chemical stability. However, its clinical application is limited by the biological inertness of PEEK. Numerous efforts have been made to improve the bioactivity of this polymer over the years. However, modification methods that can not only promote osteogenesis but also maintain excellent properties are still limited. Hence, a facile hot die formation technique is developed for establishing patterned nanorod arrays on the PEEK surface in situ. This method can maintain the excellent properties of PEEK and can be used in implantation as it can facilitate osteogenic activity in the absence of any organic/inorganic differentiation-inducing factors. PEEK with 200-nm patterned nanorod arrays on the surface exhibits excellent osteogenic properties. This result is obtained by assessing the osteogenic differentiation properties of rat adipose-derived stem cells at the gene and protein levels in vitro. In vivo experimental results reveal that the surface-modified cylindrical PEEK 200 implants present with excellent osseointegration properties. Moreover, they can tightly bind with the surrounding bone tissue. A practical method for manufacturing single-component PEEK implants with excellent osseointegration properties is reported, and the materials can be possibly used as orthopedic implants.

Download full-text PDF

Source
http://dx.doi.org/10.1002/smll.202105589DOI Listing

Publication Analysis

Top Keywords

osseointegration properties
12
patterned nanorod
12
nanorod arrays
12
exhibits excellent
8
maintain excellent
8
excellent properties
8
implants excellent
8
excellent osseointegration
8
properties
7
peek
7

Similar Publications

Synthetic bone transplantation has emerged in recent years as a highly promising strategy to address the major clinical challenge of bone tissue defects. In this field, bioactive glasses (BGs) have been widely recognized as a viable alternative to traditional bone substitutes due to their unique advantages, including favorable biocompatibility, pronounced bioactivity, excellent biodegradability, and superior osseointegration properties. This article begins with a comprehensive overview of the development and success of BGs in bone tissue engineering, and then focuses on their composite reinforcement systems with biodegradable metals, calcium-phosphorus (Ca-P)-based bioceramics, and biodegradable medical polymers, respectively.

View Article and Find Full Text PDF
Article Synopsis
  • This study reviews the current applications, limitations, and challenges of using polyetheretherketone (PEEK) in stomatology, highlighting its importance in various dental procedures.
  • Numerous studies underscore PEEK's beneficial properties, such as biocompatibility and fracture resistance, and its use in many dental applications, including implants and orthodontic devices.
  • Despite its potential, most evidence is based on short-term studies, indicating a need for more long-term clinical research to fully support PEEK's effectiveness in dentistry.
View Article and Find Full Text PDF

Promoting angiogenesis, alleviating oxidative stress injury and inflammation response are crucial for bone healing. Herein, the deferoxamine (DFO)-loaded gelatin methacryloyl (GelMA) hydrogel coating (GelMA-DFO) was constructed on the 3D-printed poly(Glycolide-Co-Caprolactone)-hydroxyapatite (PGCL-HAP) scaffold. After the hydrogel coating was established, Fourier transform infrared spectroscopy (FT-IR), X-ray diffraction (XRD), scanning electron microscope (SEM) and water contact angle measurement were employed to evaluate the characteristic and the biological properties were assessed.

View Article and Find Full Text PDF

Nonthermal plasma has been extensively utilized in various biomedical fields, including surface engineering of medical implants to enhance their biocompatibility and osseointegration. To ensure robustness and cost effectiveness for commercial viability, stable and effective plasma is required, which can be achieved by reducing gas pressure in a controlled volume. Here, we explored the impact of reduced gas pressure on plasma properties, surface characteristics of plasma-treated implants, and subsequent biological outcomes.

View Article and Find Full Text PDF

Design, characterisation, and clinical evaluation of a novel porous Ti-6Al-4V hemipelvic prosthesis based on Voronoi diagram.

Biomater Transl

September 2024

Orthopaedic Research Institute and Department of Orthopaedics, West China Hospital, Sichuan University, Chengdu, Sichuan Province, China.

Three-dimensional printed Ti-6Al-4V hemipelvic prosthesis has become a current popular method for pelvic defect reconstruction. This paper presents a novel biomimetic hemipelvic prosthesis design that utilises patient-specific anatomical data in conjunction with the Voronoi diagram algorithm. Unlike traditional design methods that rely on fixed, homogeneous unit cell, the Voronoi diagram enables to create imitation of trabecular structure (ITS).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!