Objectives: To evaluate in-hospital outcomes of concomitant mitral valve replacement (MVR) in patients undergoing conventional aortic valve replacement due to aortic stenosis in a nationwide cohort.

Methods: Administrative data from all patients with aortic stenosis undergoing conventional aortic and concomitant MVR (reason for MVR not specified) between 2017 and 2018 in Germany were analysed.

Results: A total of 2597 patients with a preoperative logistic EuroScore of 9.81 (standard deviation: 8.56) were identified. In-hospital mortality was 6.8%. An in-hospital stroke occurred in 3.4%, acute kidney injury in 16.3%, prolonged mechanical ventilation of more than 48 h in 16.3%, postoperative delirium in 15.8% and postoperative pacemaker implantation in 7.6% of the patients. Mean hospital stay was 16.5 (standard deviation: 12.1) days. Age [odds ratio (OR): 1.03; P = 0.019], New York Heart Association class III or IV (OR: 1.63; P = 0.012), previous cardiac surgery (OR: 2.85, P = 0.002), peripheral vascular disease (OR: 2.01, P = 0.031), pulmonary hypertension (OR: 1.63, P = 0.042) and impaired renal function (glomerular filtration rate <15, OR: 3.58, P = 0.001; glomerular filtration rate <30, OR: 2.51, P = 0.037) were identified as independent predictors for in-hospital mortality.

Conclusions: In this nationwide analysis, concomitant aortic and MVR was associated with acceptable in-hospital mortality, morbidity and length of in-hospital stay. The regression analyses may help to identify high-risk patients and further optimize treatment strategies.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8860409PMC
http://dx.doi.org/10.1093/icvts/ivab352DOI Listing

Publication Analysis

Top Keywords

valve replacement
12
in-hospital outcomes
8
patients undergoing
8
mitral valve
8
undergoing conventional
8
conventional aortic
8
aortic stenosis
8
standard deviation
8
patients
5
aortic
5

Similar Publications

Background: Transvenous lead extraction (TLE) has become an essential component of lead management strategies, but it carries the risk of severe complications, including damage to the tricuspid valve. Currently, there are no established predictors that can help prevent these complications.

Case Summary: An 84-year-old male with a dual-chamber pacemaker was admitted to the hospital due to a pocket fistula resulting from a local infection.

View Article and Find Full Text PDF

Background: Repair of the regurgitant bicuspid aortic valve is an attractive alternative to valve replacement. Although good long-term outcomes have been reported, postoperative aortic stenosis remains a major late cause of repair failure in bicuspid aortic valves. Sinus plication is effective for creating a more symmetrical commissural angle, leading to a decrease in the mean transvalvular pressure gradient.

View Article and Find Full Text PDF

Aims: To evaluate the association between transcatheter edge-to-edge repair (TEER) and outcomes in patients with significant mitral regurgitation (MR) following acute myocardial infarction (MI), focusing on the aetiology of acute post-MI MR in high-risk surgical patients.

Methods And Results: The International Registry of MitraClip in Acute Mitral Regurgitation following Acute Myocardial Infarction (IREMMI) includes 187 patients with severe MR post-MI managed with TEER. Of these, 176 were included in the analysis, 23 (13%) patients had acute papillary muscle rupture (PMR) and 153 (87%) acute secondary MR.

View Article and Find Full Text PDF

Background: Transcatheter closure of percutaneous paravalvular leak (PVL) is a technically challenging procedure, especially after surgical mechanical valve replacements (SMVR), as the risk of interference with the prosthetic valve discs and the complex interventional techniques required for mitral PVL closure. Our study was designed to review the results with transcatheter closure of PVL after SMVR.

Methods: From January 2018 through December 2023, a total of 64 patients with PVL after SMVR underwent transcatheter closure with the help of preoperative 3-dimensional printing model and simulator for image evaluation.

View Article and Find Full Text PDF

Rationale: Warfarin is the most commonly used drug in patients with mechanical valve replacement. Acute liver damage after warfarin is rare but potentially harmful. We present a case of warfarin-induced gastrointestinal bleeding with liver injury, pharmacy monitoring, and its therapy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!