Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/europace/euab302 | DOI Listing |
BMC Sports Sci Med Rehabil
January 2025
Department of Sport Exercise and Rehabilitation, Northumbria University, Newcastle upon Tyne, UK.
Background: Fatigue and inactivity are linked to decreased health-related quality of life (HRQoL) in chronic conditions. A multidimensional approach to activity pacing may improve HRQoL by promoting physical activity (PA) and alleviating fatigue. Addressing fatigue across chronic conditions is crucial, especially when underlying causes are unknown.
View Article and Find Full Text PDFEur Heart J Case Rep
January 2025
Department of Cardiology, Yokohama City University Hospital, 3-9 Fukuura, Kanazawa-Ku, Yokohama city, Kanagawa 236-0004, Japan.
Background: Coronary sinus (CS) lead placement in persistent left superior vena cava (PLSVC) cases is challenging because of the poor backup force of the guiding catheter within the enlarged CS. Active fixation Quadripolar leads (Attain Stability™ Quad 4798, Medtronic) can expand choice to CS branches with limited access; however, no cases of anchoring to the main body of the CS have been published to date.
Case Summary: We describe a case of cardiac resynchronization therapy pacemaker upgrade in a 79-year-old female who developed pacing-induced cardiomyopathy after pacemaker implantation via the right superior vena cava (SVC) for atrioventricular block eight years ago wherein PLSVC was revealed during the procedure.
Int J Sports Physiol Perform
January 2025
M2S Laboratory (Movement, Sport & Health), University Rennes 2, Bruz, France.
Purpose: To investigate technical regulation mechanisms of long-distance swimmers that differentiate optimal pacing strategies and the underlying kinematic parameters.
Methods: Twenty-one national and international swimmers were equipped with a sacrum-worn inertial measurement unit performed during 5000-m indoor French championships. Percentage of critical swimming speed (CSS), stroke rate, stroke length, jerk cost, stroke index, and mechanical proficiency score were computed by lap.
Pacing Clin Electrophysiol
January 2025
Department of Cardiology, Yan'an Hospital Affiliated to Kunming Medical University, Kunming, Yunnan, P.R. China.
Objective: The Vizigo sheath, a novel visualizable steerable sheath, has been utilized effectively in the clinical management of atrial fibrillation. However, its application in the ablation of typical atrial flutter (AFL) remains unexplored. This study aims to evaluate and compare the efficacy and safety of the Vizigo sheath against a conventional fixed sheath during catheter ablation for typical AFL.
View Article and Find Full Text PDFPacing Clin Electrophysiol
January 2025
Second Division of Cardiology, Cardiac-Thoracic and Vascular Department, University Hospital of Pisa, Pisa, Italy.
This case details the successful implantation of a leadless pacemaker following the extraction of transvenous leads in a 72-year-old female patient with a complex cardiovascular history. The patient had undergone a series of cardiac interventions, including a recent percutaneous tricuspid valve repair with a metal clip implant due to severe regurgitation. After presenting with an infection at the pacemaker site, methicillin-resistant Staphylococcus hominis was identified, necessitating the removal of the entire pacing system.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!