Speech detection and discrimination ability are important measures of hearing ability that may inform crucial audiological intervention decisions for individuals with a hearing impairment. However, behavioral assessment of speech discrimination can be difficult and inaccurate in infants, prompting the need for an objective measure of speech detection and discrimination ability. In this study, the authors used functional near-infrared spectroscopy (fNIRS) as the objective measure. Twenty-three infants, 2 to 10 months of age participated, all of whom had passed newborn hearing screening or diagnostic audiology testing. They were presented with speech tokens at a comfortable listening level in a natural sleep state using a habituation/dishabituation paradigm. The authors hypothesized that fNIRS responses to speech token detection as well as speech token contrast discrimination could be measured in individual infants. The authors found significant fNIRS responses to speech detection in 87% of tested infants (false positive rate 0%), as well as to speech discrimination in 35% of tested infants (false positive rate 9%). The results show initial promise for the use of fNIRS as an objective clinical tool for measuring infant speech detection and discrimination ability; the authors highlight the further optimizations of test procedures and analysis techniques that would be required to improve accuracy and reliability to levels needed for clinical decision-making.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8671543PMC
http://dx.doi.org/10.1038/s41598-021-03595-zDOI Listing

Publication Analysis

Top Keywords

detection discrimination
16
speech detection
16
speech token
12
discrimination ability
12
speech
10
token detection
8
individual infants
8
functional near-infrared
8
near-infrared spectroscopy
8
speech discrimination
8

Similar Publications

Michael and Schiff-Base Reactions-Assisted Fluorescence Sensor Based on the MOF Nanosheet Microspheres for the Effective Discrimination and Detection of Hydroquinone and Catechol.

Anal Chem

January 2025

Center of Advanced Analysis and Gene Sequencing, Key Laboratory of Molecular Sensing and Harmful Substances Detection Technology, Zhengzhou University, Kexue Avenue 100, Zhengzhou, Henan 450001, P. R. China.

A novel sensing platform was constructed for the recognition and identification of dihydroxybenzene isomers based on the MOF-0.02TEA fluorescence sensor with the morphology of nanosheet microspheres through coordination modulation. Based on the sensing principle that the amino group on the MOF-0.

View Article and Find Full Text PDF

Abnormal locomotor patterns may occur in case of either motor damages or neurological conditions, thus potentially jeopardizing an individual's safety. Pathological gait recognition (PGR) is a research field that aims to discriminate among different walking patterns. A PGR-oriented system may benefit from the simulation of gait disorders by healthy subjects, since the acquisition of actual pathological gaits would require either a higher experimental time or a larger sample size.

View Article and Find Full Text PDF

Deep learning-based morphometric analysis of zebrafish is widely utilized for non-destructively identifying abnormalities and diagnosing diseases. However, obtaining discriminative and continuous organ category decision boundaries poses a significant challenge by directly observing zebrafish larvae from the outside. To address this issue, this study simplifies the organ areas to polygons and focuses solely on the endpoint positioning.

View Article and Find Full Text PDF

Background/objectives: Gut microbiota interacts with nutrients, which may be relevant to assigning a microbial signature to colorectal cancer (CRC). We aim to evaluate the potential of gut microbiota combined with dietary habits in the early detection of pathological findings related to CRC in the course of a screening program.

Methodology: The colonoscopy performed on 152 subjects positive for fecal occult blood test showed that 6 subjects had adenocarcinoma, 123 had polyps, and 23 subjects had no pathological findings.

View Article and Find Full Text PDF

The authentication of Ziziphi Spinosae Semen (ZSS), Ziziphi Mauritianae Semen (ZMS), and Hovenia Acerba Semen (HAS) has become challenging. The chromatic and textural properties of ZSS, ZMS, and HAS are analyzed in this study. Color features were extracted via RGB, CIELAB, and HSI spaces, whereas texture information was analyzed via the gray-level co-occurrence matrix (GLCM) and Law's texture feature analysis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!