Evaluation of quantitative light-induced fluorescence to assess lesion depth in cavitated and non-cavitated root caries lesions - An in vitro study.

Photodiagnosis Photodyn Ther

Department of Cariology, Endodontology and Periodontology, University of Leipzig, Liebigstr. 12, Leipzig 04103, Germany. Electronic address:

Published: March 2022

Background: This in vitro study aimed to assess carious lesions on root surfaces using quantitative light-induced fluorescence (QLF) and to compare the readings with axial lesion depth on µCT.

Methods: The root surfaces of 107 extracted human teeth were included after visual-tactile inspection. For further analysis, the following parameters were assessed: clinical findings (non-cavitated: leathery or hard, cavitated), QLF- (QLF-D Biluminator 2+), and µCT-images (Bruker Skyscan 1172). The shape of the undamaged tooth surface of the cavitated lesions was virtually re-constructed during µCT analysis. Clinical surface texture,% fluorescence loss, and lesion depth (µCT) were determined.

Statistical Analysis: chi²-test, Spearman-Rho test, regression analysis.

Results: ∆F was significantly lower in non-cavitated leathery (-50.37 ± 15.10) and cavitated (-61.23 ± 9.92) compared to non-cavitated surfaces with a hard texture (-17.04 ± 16.10, p < 0.01). For non-cavitated surfaces, a negative correlation was observed between ∆F and lesion depth in µCT images regardless of texture (-0.748, p < 0.01). Regression analysis revealed that ∆F predicted lesion depth in µCT for non-cavitated surfaces (β: 0.703, CI95: 0.67--0.43, p < 0.01).

Conclusion: The percentage of fluorescence loss (∆F) in QLF predicted lesion depth of non-cavitated demineralized root surfaces. Therefore, QLF can be recommended for estimating the lesion depth of carious root lesions and seems to expand the possibilities of follow-up and lesion monitoring, especially for non-cavitated surfaces.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.pdpdt.2021.102675DOI Listing

Publication Analysis

Top Keywords

lesion depth
12
quantitative light-induced
8
light-induced fluorescence
8
vitro study
8
root surfaces
8
non-cavitated leathery
8
evaluation quantitative
4
fluorescence assess
4
assess lesion
4
cavitated
4

Similar Publications

In Vivo Tissue Temperature Characteristics of Contact Force Catheter With a Mesh-Shaped Irrigation Tip: A Porcine Study.

Pacing Clin Electrophysiol

January 2025

Section of Laboratory for Animal Experiments, Institute of Medical Science, Medical Research Support Center, Nihon University, School of Medicine, Tokyo, Japan.

Background: Neither the actual in vivo tissue temperatures reached with a novel contact force sensing catheter with a mesh-shaped irrigation tip (TactiFlex SE, Abbott) nor the safety profile has been elucidated.

Methods: In a porcine model (n = 8), thermocouples were implanted epicardially in the superior vena cava, right pulmonary vein, and esophagus close to the inferior vena cava following a right thoracotomy. After chest closure, endocardial ablation was conducted near the thermocouples under fluoroscopic guidance.

View Article and Find Full Text PDF

Aims: This study aimed to evaluate the enamel remineralization effect of fluoride-incorporated bioactive glass (F-BG) toothpaste on artificial subsurface caries in primary teeth.

Materials And Methods: Forty sound primary maxillary incisors were subjected to a demineralizing solution for four days to induce artificial enamel caries. The teeth were randomly divided into four experimental groups ( = 10 per group): Group I, F-BG toothpaste (530 ppm fluoride) (BiominF); Group II, 0.

View Article and Find Full Text PDF

Chronic inflammation in the tumour microenvironment (TME) via Th2-polarisation promotes melanoma progression and metastasis, making it a target for immunotherapy. Interleukin (IL)-4 is considered essential for Th2-polarisation in the TME; however, its source remains unknown. Basophils have been postulated as one of its sources.

View Article and Find Full Text PDF

Purpose: The aim of this study was to examine the experiences of women diagnosed with precancerous cervical lesions, and their spouses, according to the Roy Adaptation Model.

Method: A phenomenological design was used in this study, with its conceptual framework being formed by the Roy Adaptation Model. The sample was composed of women with precancerous cervical lesions (n:23) and their spouses (n:5).

View Article and Find Full Text PDF

Objectives: To compare the safety and efficacy of debulking devices, including directional atherectomy (DA) and excimer laser atherectomy (ELA), when combined with drug-coated balloons (DCB) for treating de novo femoropopliteal atherosclerotic obliterans (ASO). Additionally, to evaluate the long-term outcomes and application status of these different debulking devices.

Methods: Clinical data were collected from patients with femoropopliteal ASO who underwent combined debulking and DCBs at the Vascular Surgery Department of Xuanwu Hospital, Capital Medical University, China, between January 2018 and January 2023.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!