Volatile sulfur compounds (VSCs) are key odorous compounds from emissions of various odour sources because they are odorous and generally have very low odour threshold values. Identification and quantification of them through air server-thermal desorber-gas chromatography-sulfur chemiluminescence detector (AS-TD-GC-SCD) become more and more popular, although VSCs can be determined by other detectors. To find a valid, practical and quick calibration method is also an important step in their analytical processes. This study compared three different sample preparation and unity sampling methods using both gas standards (with 10 VSCs balanced in pure nitrogen gas) and liquid standards of 7 VSCs. For liquid standard sample preparation, two solvents (methanol and n-pentane) were tested and their calibration results were compared. The study revealed that the three calibration methods with both manual and dynamic dilution of VSC standard gases can achieve satisfactory calibration results with nice linear regression and correlation coefficient (r). The dynamic dilution and loop sampling method is recommended because of its better reliability and time-saving processing. For calibration of VSCs with liquid standards, preparing the samples using dissolved VSCs in n-pentane and analysing them using the loop sampling method achieved best calibration results. For dimethyl trisulfide (DMTS), its calibration cannot obtain as good results as other sulfur compounds even using the best performance calibration method.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s10661-021-09690-y | DOI Listing |
Br J Radiol
January 2025
Radiotherapy Physics Dept, Ipswich Hospital, Ipswich, Suffolk, IP45PD, UK.
Objectives: To survey kilovoltage (kV) radiotherapy in the UK, updating a 2016 study, focussing on radiotherapy physics, including equipment quality control (QC) and radiation dosimetry, with information on installed equipment and clinical activity.
Methods: All UK radiotherapy physics departments (n = 68) were invited to complete a comprehensive survey. An analysis of the installed equipment base, patient numbers, clinical activity, QC testing and radiation dosimetry processes were undertaken.
Rev Sci Instrum
January 2025
Beijing National Laboratory for Condensed Matter Physics, Institute of Physics, Chinese Academy of Sciences, Beijing 100190, China.
We design and construct an ultrafast optical spectroscopy instrument that integrates both on-site in situ high-pressure technique and low-temperature tuning capability. Conventional related instruments rely on off-site tuning and calibration of the high pressure. Recently, we have developed an on-site in situ technique, which has the advantage of removing repositioning fluctuation.
View Article and Find Full Text PDFOtolaryngol Head Neck Surg
January 2025
Department of Otolaryngology-Head and Neck Surgery, University of Washington, Seattle, Washington, USA.
Objective: To validate the use of neural radiance fields (NeRF), a state-of-the-art computer vision technique, for rapid, high-fidelity 3-dimensional (3D) reconstruction in endoscopic sinus surgery (ESS).
Study Design: An experimental cadaveric pilot study.
Setting: Academic medical center.
Nanomaterials (Basel)
December 2024
Department of Computer Engineering, Modeling, Electronics, and Systems Engineering, University of Calabria, 87036 Rende, Italy.
This paper presents Cryo-SIMPLY, a reliable smart material implication (SIMPLY) operating at cryogenic conditions (77 K). The assessment considers SIMPLY schemes based on spin-transfer torque magnetic random access memory (STT-MRAM) technology with single-barrier magnetic tunnel junction (SMTJ) and double-barrier magnetic tunnel junction (DMTJ). Our study relies on a temperature-aware macrospin-based Verilog-A compact model for MTJ devices and a 65 nm commercial process design kit (PDK) calibrated down to 77 K under silicon measurements.
View Article and Find Full Text PDFOral Dis
January 2025
Laboratory of Clinical Pharmaceutics & Therapeutics, Faculty of Pharmaceutical Sciences, Hokkaido University, Sapporo, Japan.
Objectives: To externally validate a clinical prediction model for surgical site infection (SSI) after lower third molar (L3M) surgery and evaluate its clinical usefulness.
Methods: We conducted a retrospective cohort study of patients who underwent L3M surgery at Hokkaido University Hospital. The study was designed to evaluate the historical and methodological transportability.