Objectives: The aim of this study was to determine the feasibility of ultrasonographically measuring the caudal vena cava (CVC) at the subxiphoid view of healthy, lightly sedated cats in a standing position and lateral recumbency.
Methods: This was a prospective, observational, experimental single-centre study. Twenty healthy research-purposed cats were enrolled. Two trained operators scanned each cat in two positions - standing and lateral recumbency - in a randomised order. CVC diameter was measured at the narrowest diameter during inspiration and at the widest diameter during expiration, at two anatomical locations along the CVC - where the CVC crosses the diaphragm (base) and 2 mm caudal to the diaphragm. The CVC collapsibility index (CVC-CI) was calculated for each site. Normalcy was assessed with a Shapiro-Wilk test. A one-way ANOVA with post-hoc Tukey's test was used to compare inspiratory with expiratory values within and between groups. A paired -test compared the CVC-CI between groups ( ⩽0.05 indicated statistical significance). Spearman's correlation and Bland-Altman analysis assessed inter-operator variability.
Results: All ultrasonographic data passed normalcy and were reported as mean ± SD. When compared with each other, inspiratory and expiratory values were statistically different for position, location and operator (all <0.0001). There was no statistically significant difference between lateral recumbency or standing position for inspiratory, expiratory and CVC-CI values. Inter-operator variability was substantial, with operator 2 consistently obtaining smaller measurements than operator 1. The mean CVC-CI in lateral recumbency at the base was 24% for operator 1 and 37% for operator 2. For the same site in standing position, CVC-CI was 27% and 41% for operators 1 and 2, respectively.
Conclusions And Relevance: This pilot study demonstrates that it is possible to ultrasonographically measure the CVC diameter in both lateral recumbency and a standing position in healthy, lightly sedated cats. However, measurements obtained are operator dependent with variability between individuals. Further studies are needed to determine if ultrasonographic CVC assessment will prove helpful in estimating intravascular volume status in cats.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10812311 | PMC |
http://dx.doi.org/10.1177/1098612X211064697 | DOI Listing |
Int J Nanomedicine
December 2024
Key Laboratory of Bioresources and Eco-Environment of Ministry of Education, College of Life Science, Sichuan University, Chengdu, People's Republic of China.
Introduction: The proliferation of nanoplastics (NPs) has emerged as a significant environmental concern due to their extensive use, raising concerns about potential adverse effects on human health. However, the exact impacts of NPs on the early development of hematopoietic organs remain poorly understood.
Methods: This investigation utilized fluorescence microscopy to observe the effects of various NP concentrations on the caudal vein plexus (CVP) development in zebrafish embryos.
J Feline Med Surg
December 2024
School of Veterinary Science, The University of Queensland, Gatton, QLD, Australia.
Objectives: The primary objective of this investigation was to ultrasonographically evaluate the caudal vena cava to aorta (CVC:Ao) ratio in healthy, conscious cats and to generate reference intervals. A secondary objective was to identify the site of examination with the least intra- and inter-observer variability. This investigation was undertaken to assess whether the CVC:Ao ratio holds promise as a technique to assess intravascular volume responsiveness in cats.
View Article and Find Full Text PDFAnat Histol Embryol
January 2025
Faculty of Veterinary Medicine, Teaching and Clinical Department of Companion Animals, FARAH, University of Liège, Liège, Belgium.
Computed tomographic (CT) characterisation of abdominal vessels is poorly studied. The objectives of this retrospective study were to assess during growth, by CT angiography, the evolution of the aorta (Ao), caudal vena cava (CVC), portal vein (PV), length of the second lumbar vertebra (L2) and different ratios between these structures; and to determine the influence of weight and age on the vessels' sizes and ratios. The first group included six beagles scanned every month from 4 to 12 months old, then every 3 months up to 24 months old.
View Article and Find Full Text PDFVet Med Sci
January 2025
Department of Veterinary Medical Imaging, College of Veterinary Medicine, Jeonbuk National University, Iksan, Jeollabuk-do, Republic of Korea.
A 13-year-old intact female Shih Tzu presented with anorexia, panting and pain of unknown origin. Physical examination was normal except for a systolic murmur (grade 3/6). Abdominal radiographs revealed an ill-defined area of increased opacity in the mid-abdomen.
View Article and Find Full Text PDFPrevious studies have described two distinct vascular systems in cetacean fins. However, these studies have been limited to Delphinoidea species, with little information on their three-dimensional structures. In this study, the anatomical analysis of the caudal and dorsal fins of a dwarf sperm whale was conducted using X-ray computed tomography and gross dissection with staining, providing the first confirmation of the two vascular systems in the fins of the family Kogiidae.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!