BACKGROUND In the craniocervical junction, a C1-C2 pedicle screw-rod (PSR) fixation is applied to provide stability. The horizontal rod-rod crosslink (hR-R CL) is often used to enhance segmental posterior instrumentation. However, the biomechanics of the alternative horizontal screw-screw crosslink (hS-S CL) in the craniocervical junction are unclear. MATERIAL AND METHODS A nonlinear atlantoaxial instability 3-dimensional C1-C2 finite element model was constructed using computed tomography images. On this basis, 2 fixation models were established with C1-C2 PSR fixation using (1) a rod-rod crosslink (R-R CL), and (2) a screw-screw crosslink (S-S CL). Range of motion (ROM) of the atlantoaxial joint, stress distribution of the implants, and maximum stress value of the vertebral bodies were calculated and compared under 4 loading conditions, including flexion, extension, lateral bending, and axial rotation. RESULTS Atlantoaxial joint ROM was reduced by 90.19% to 98.5% with the hR-R CL, and by 90.1% to 98.7% with the hS-S CL, compared with the instability model. During axial rotation, the total stress peak of the PSR fixation was smaller with hS-S CL than with hR-R CL. The peak stress values of the vertebral bodies were comparable between the 2 fixation models. CONCLUSIONS The 2 tested crosslink models provided comparable stability. However, during axial rotation, the total stress peak of hS-S CL fixation was smaller than that of hR-R CL fixation. Since the atlantoaxial joint primarily functions as a rotational joint, our results suggested that the use of hS-S CL can provide a more stable environment for the implants.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8684241PMC
http://dx.doi.org/10.12659/MSM.932026DOI Listing

Publication Analysis

Top Keywords

screw-screw crosslink
12
psr fixation
12
atlantoaxial joint
12
axial rotation
12
finite element
8
horizontal screw-screw
8
c1-c2 pedicle
8
pedicle screw-rod
8
fixation
8
craniocervical junction
8

Similar Publications

Study Design: This is a biomechanical study in vitro.

Objective: To investigate the biomechanical differences between horizontal rod-rod crosslink (hR-R CL) and the horizontal screw-screw crosslink (hS-S CL) implementation in C1-2 pedicle screw-rod (C1-2 PSR) fixation.

Summary Of Background: To improve internal fixation stability, transverse connector (TC) is used in C1-2 PSR to increase torsional stiffness.

View Article and Find Full Text PDF

BACKGROUND In the craniocervical junction, a C1-C2 pedicle screw-rod (PSR) fixation is applied to provide stability. The horizontal rod-rod crosslink (hR-R CL) is often used to enhance segmental posterior instrumentation. However, the biomechanics of the alternative horizontal screw-screw crosslink (hS-S CL) in the craniocervical junction are unclear.

View Article and Find Full Text PDF

Background Context: Children with early onset scoliosis benefit from early operative treatment with dual growing rods as they provide an "internal brace" for the spine and allow curve correction and sequential lengthenings to maximize thoracic cage development. The foundations that provide anchor points for the dual growing rods may incorporate hooks, screws, or a hybrid construct. It is unclear how stable different types of foundation constructs are with regard to pullout.

View Article and Find Full Text PDF

Background Context: Cross-link systems have been used to augment segmental spinal instrumentation since the earliest introduction of these fixation systems. Although transverse cross-links have little impact on sagittal motion of spinal constructs, cross-linkage does affect torsional rigidity. Despite the wide variety of cross-link designs, almost all have been configured as transverse devices.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!