Hybrid Room: Does it Offer Better Accuracy in the Proximal Deployment of Infrarenal Aortic Endograft?

Ann Vasc Surg

Service de chirurgie vasculaire, Centre de l'Aorte, CHU Lille, Lille, France; Univ. Lille, U1008 - Controlled Drug Delivery Systems and Biomaterials, Lille, France.

Published: May 2022

Background: This work aims to evaluate the impact of hybrid rooms and their advanced tools on the accuracy of proximal deployment of infrarenal bifurcated endograft (EVAR).

Methods: A retrospective single center analysis was conducted between January 2015 and March 2019 including consecutive patients that underwent EVAR. Groups were defined whether the procedure was performed in a hybrid operating room (HOR group) or using a mobile 2D fluoroscopic imaging system (non-HOR group). The accuracy of the proximal deployment was estimated by the distance (mm) between the bottom of the lowest renal artery (LwRA) origin and the endograft radiopaque markers parallax (LwRA/EDG distance) after curvilinear reconstruction. The impact of HOR on the LwRA/EDG distance was investigated using a multiple linear regression model. A composite "proximal neck"-related complications event was studied (Cox models).

Results: Overall, 93 patients (87 %male, median age 73 years) were included with 49 in the HOR group and 44 in the non-HOR group. Preoperative CTA analysis of the proximal neck exhibited similar median length, but different median aortic diameter (P = 0.012) and median beta angulation (P = 0.027) between groups. The median LwRA/EDG distance was shorter in the HOR group (multivariate model, P = 0.022). No difference in "proximal neck"-related complications was evidenced between the HOR and non-HOR groups (univariate analysis, P = 0.620). Median follow-up time was respectively 25 [14-28] and 36 months [23-44] in the HOR group and in the non-HOR group (P < 0.001).

Conclusion: HOR offer more accurate proximal deployment of infrarenal endografts, with however no difference in "proximal neck"-related complications between groups.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.avsg.2021.11.009DOI Listing

Publication Analysis

Top Keywords

proximal deployment
16
hor group
16
accuracy proximal
12
deployment infrarenal
12
non-hor group
12
lwra/edg distance
12
"proximal neck"-related
12
neck"-related complications
12
group non-hor
8
difference "proximal
8

Similar Publications

Intrasaccular flow disruption has become established for the treatment of wide necked and bifurcation aneurysms. The most successful current devices are the WEB (Microvention) and Contour (Stryker). The Artisse (Medtronic) is a novel intrasaccular device designed to treat a variety of aneurysm morphologies.

View Article and Find Full Text PDF

The management of gastrointestinal anastomotic leaks post surgery is a considerable challenge, characterized by elevated morbidity and mortality, particularly in cases of esophageal-jejunal anastomotic leaks. Diverse endoscopic intervention techniques have been utilized with enhanced success. We present a case where a 57-year-old patient with Siewert type II esophageal cardia cancer underwent endoscopic deployment of a fully covered stent into a fistula resulting from anastomotic leakage, following a laparoscopic proximal gastrectomy with Roux-en-Y and double tract reconstruction.

View Article and Find Full Text PDF

This case report describes a unique presentation of May-Thurner syndrome (MTS) in a 28-year-old woman, characterized by the congenital bifurcation of the left common iliac vein (LCIV) into the outer (OLCIV) and inner (ILCIV) segments. Both veins experienced significant compression - OLCIV proximally and ILCIV medially - due to the overlying right common iliac artery (RCIA) and lumbar spine. The patient presented with bilateral spider veins, lower extremity swelling, pelvic discomfort, and bilateral leg cramping.

View Article and Find Full Text PDF

The use of conduction system pacing (CSP) in adults with congenital heart disease (CHD) is growing, however data remain limited. In patients with congenitally corrected transposition of the great arteries following the double switch operation, existing CSP tools and techniques require modification to allow for the anterior displacement of the atrioventricular node and proximal conduction system in addition to navigating the tortuous route of the atrial redirection. We report the successful use of CSP focusing on the technique of delivery tool modification to allow stability on the basal septum for deployment to the area of the distal His bundle and proximal left bundle branch.

View Article and Find Full Text PDF

Novel dilation-erosion labeling technique allows for rapid, accurate and adjustable alignment measurements in primary TKA.

Comput Biol Med

December 2024

Department of Orthopaedic Surgery, Vanderbilt University Medical Center, 1215 21st Avenue South, Nashville, TN, 37232, USA; Vanderbilt Institute for Surgery and Engineering, 1161 21st Ave South, Nashville, TN, 37212, USA. Electronic address:

Background: Optimal implant position and alignment remains a controversial, yet critical topic in primary total knee arthroplasty (TKA). Future study of ideal implant position will require the ability to efficiently measure component positions at scale. Previous algorithms have limited accuracy, do not allow for human oversight and correction in deployment, and require extensive training time and dataset.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!