The study aims to establish a new method in the Tetralogy of Fallot (ToF) called the pulmonary valve bi-orifice method (pulmonary annular sparing with an individualized autologous pericardial patch; thus, two orifices are formed at the level of the pulmonary valve annulus) to reconstruct the right ventricular outflow tract (RVOT). A retrospective analysis of 128 TOF patients from October 2009 to June 2018 with severe pulmonary valve dysplasia who underwent transvalvular annular patch (TAP) procedure (control group) or an individualized pulmonary valve bi-orifice procedure (observation group) were studied. The RVOT for each patient in the observation group was individually reconstructed per the patient's weight and the size of the autologous pulmonary valve using the bi-orifice method; however, increasing the cross-sectional area of the pulmonary valve annulus without destroying its integrity. The result was then compared to the control group, where TAP procedures were applied to evaluate the short to mid-term outcome(s). An simulation test was used to verify the anti-regurgitation mechanism of the new method. The simulation test indicated that the anti-regurgitation mechanism was completed by the pericardial patch and the autologous pulmonary valve movement toward each other. Thus, for clinical applications, patients in both groups were compared. The results showed no significant differences in cardiopulmonary bypass and aortic cross-clamp time, mechanical ventilation, and ICU and post-operative residence between the two groups. During the follow-up period (3- to 12-years), 14 patients in the observation group had mild regurgitation after surgery (22.2%), while 10 patients had moderate pulmonary regurgitation (15.8%) with no right ventricular (RV) dilation. On the other hand, 22 patients (39.6%) had moderate to severe regurgitation in the control group, while left pulmonary artery stenosis occurred in one patient. In the control group, six patients (9.2%) with severe RV dilation were reoperated. Individualized pulmonary valve bi-orifice procedure is a safe and excellent method for reconstructing RVOT in ToF.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8661005PMC
http://dx.doi.org/10.3389/fcvm.2021.772198DOI Listing

Publication Analysis

Top Keywords

pulmonary valve
32
valve bi-orifice
16
control group
16
pulmonary
12
individualized pulmonary
12
observation group
12
ventricular outflow
8
outflow tract
8
tetralogy fallot
8
valve
8

Similar Publications

Reversed valved Potts shunt for refractory primary pulmonary arterial hypertension.

Multimed Man Cardiothorac Surg

January 2025

• Pediatric and Congenital Cardiac Surgery, LMU University Hospital, Munich, Germany • Congenital Cardiac Surgery, German Heart Center Munich, Munich, Germany • European Pediatric Heart Center EKHZ Munich, Munich, Germany.

This procedure is carried out via a full sternotomy using standard aortic and bicaval cannulations. For the aortic and pulmonary anastomoses, selective antegrade unilateral cerebral perfusion is used after cooling the body temperature to 26 °Celsius. A 12-mm Hancock conduit is interposed between the pulmonary artery and the proximal descending aorta using standard running suture techniques.

View Article and Find Full Text PDF

Background: The 'univentricular' heart encompasses a variety of congenital cardiac defects characterized by a single functional ventricle and an underdeveloped ventricular chamber. Surgical intervention, typically in infancy or childhood, aims to regulate pulmonary blood flow volume. In adulthood, untreated patients may experience limitations in physical activity and elevated morbidity due to persistent cyanosis and arrhythmias, notably after the Fontan procedure.

View Article and Find Full Text PDF

Background: Patients with pulmonary atresia and ventricular septal defect (PA/VSD) are prone to progressive aortic dilation. However, there are relatively few reports of progressive development of aortic aneurysm or aortic dissection in adult patients who missed early corrective surgery.

Presentation Of Cases: Case 1: A 38-year-old man with PA/VSD and a bicuspid aortic valve (BAV), underwent VSD repair, aortic valve replacement, and PA correction at age 21.

View Article and Find Full Text PDF

Right Ventricular Function and Outcomes Stratified by the Effective Regurgitant Orifice Area in Secondary Tricuspid Regurgitation.

Can J Cardiol

January 2025

Department of Cardiology, Istituto Auxologico Italiano, IRCCS, Milan, Italy; Department of Medicine and Surgery, University of Milano- Bicocca, Milan, Italy.

Background: In patients with moderate and severe secondary tricuspid regurgitation (STR), the effective regurgitant orifice area (EROA), corrected using the proximal isovelocity surface area (PISA) method for tricuspid valve leaflet tethering and low TR jet velocities, has an unclear threshold for identifying high-risk patients. This study aimed to establish a risk-based EROA cutoff and assess the impact of right ventricular (RV) remodeling on outcomes in low-risk STR patients according to EROA.

Methods: We included 513 consecutive outpatients (age 75±13 years, 47% male) with moderate and severe STR.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!