A flow-diverter (FD) device is a well-established tool for the treatment of unruptured intracranial aneurysms. Time-of-flight (TOF) MR angiography (MRA) is widely used for postoperative assessment after the treatment with FD; however, it cannot fully visualize intra-aneurysmal and intrastent flow signals due to the magnetic susceptibility from the FD. Recently, the utility of MRA with ultra-short TE (UTE) sequence and arterial spin labeling technique in assessing the therapeutic efficacy of intracranial aneurysms treated with metallic devices has been reported, but long image acquisition time is one of the drawbacks of this method. Herein, we introduce a novel UTE MRA using the subtraction method that enables the reduction in susceptibility artifacts with a short image acquisition time.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9849415PMC
http://dx.doi.org/10.2463/mrms.tn.2021-0106DOI Listing

Publication Analysis

Top Keywords

intracranial aneurysms
12
subtraction method
8
aneurysms treated
8
flow-diverter device
8
image acquisition
8
acquisition time
8
ultra-short echo-time
4
echo-time angiography
4
angiography combined
4
combined subtraction
4

Similar Publications

Objective: Giant aneurysms of the cavernous segment of the internal carotid artery presenting as acute ischemic stroke (AIS) are rare and often misdiagnosed. Limited treatment experience further complicates management.

Case Presentation: A 70-year-old female presented with acute right middle cerebral artery (MCA) occlusion due to a dislodged thrombus from a giant internal carotid aneurysm.

View Article and Find Full Text PDF

The clinical manifestation of intracranial mycotic aneurysms (ICMAs), which are rare but carry high risks of rupture and early mortality, remains poorly understood. We present a case of an ICMA that rapidly developed and ruptured after the diagnosis of meningitis caused by (), which rarely causes bacterial meningitis. A 54-year-old man presented with a headache that worsened on coughing, without altered consciousness or vomiting.

View Article and Find Full Text PDF

Purpose: Although both accessory middle cerebral artery (MCA) of distal origin and anterior communicating artery (ACoA) duplication are not rare anatomical variations, their combination is extremely rare and there are only a few reports of such combinations.

Methods: We report a case of distal origin accessory MCA associated with ACoA duplication diagnosed by magnetic resonance angiography (MRA).

Results: A 63-year-old man visited another hospital for screening examinations for cerebrovascular disease.

View Article and Find Full Text PDF

Objectives: To evaluate the prevalence and predictors of ischemic lesions on thin-slice DWI (2 mm) in endovascular treatments for unruptured intracranial aneurysms (UIA), particularly explore the potential relationship with pathway plaques.

Methods: Participants eligible for endovascular treatments with UIA at a national stroke center between March 2023 and August 2023 were prospectively enrolled. All participants performed thin-slice DWI (slice thickness of 2 mm) before and after procedures.

View Article and Find Full Text PDF

Background: The integration of robotics into neuroendovascular surgery has the potential to revolutionize the field by enhancing precision, reducing procedure-related risks, and improving patient outcomes. The CorPath GRX system represents a significant advancement in this domain. In this systematically conducted scoping review, we explore the current applications, advances, and challenges associated with robot-assisted neuroendovascular surgery.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!