Age and clinical signs as predictors of COVID-19 symptoms and cycle threshold value.

Libyan J Med

Université de Sousse, Hôpital Farhat Hached, Sousse, Laboratoire de Recherche "Insuffisance Cardiaque" (lr12sp09), Sousse, Tunisie.

Published: December 2022

Many COVID-19 infected people remain asymptomatic, and hence the diagnosis at first presentation remains a challenge. Assessment at a presentation in primary care settings is usually done by visual triaging and basic clinical examination. This retrospective study involved investigating the medical e-records of COVID-19 positive patients who presented to a COVID-19 centre in Qatar for July 2020. The presence (symptomatic group) or the absence (asymptomatic group) of symptoms along with objective vital examination (; heart-rate (HR), temperature, haemoglobin saturation (SpO)) were analysed and linked to the viral load (; cycle threshold (Ct)) of COVID-19 positive patients. Four hundred eighty-one symptomatic (230 males) and 216 asymptomatic (101 males) patients were included. Compared to the asymptomatic male group, the symptomatic male group was older, had lower Ct value and SpO, and higher temperature and HR. Compared to the females asymptomatic group, the symptomatic females group had lower Ct value, and higher temperature. Compared to the asymptomatic group, the symptomatic group had lower Ct value and SpO, and higher temperature and HR. Compared to the asymptomatic group, the symptomatic group had lower Ct values (age groups [21-30], [31-40], [41-50] and [51-60]), higher temperature (age groups [21-30] and [31-40], Ct ranges [20.01-25.00] and [25.01-30.00]), higher HR (age groups [21-30] and [31-40], Ct range [15.01-20.00]); and lower SpO (age groups [41-50] and [51-60], Ct ranges [15.01-20.00] and [35.01-40.00]). Compared with asymptomatic patients, symptomatic patients with COVID-19 are most likely to be febrile, tachycardic, hypoxic and having higher viral load. Higher viral load was associated with higher HR, higher temperature, lower SpO, but there was no relation between viral load and age.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8667934PMC
http://dx.doi.org/10.1080/19932820.2021.2010337DOI Listing

Publication Analysis

Top Keywords

higher temperature
20
asymptomatic group
16
viral load
16
compared asymptomatic
16
group symptomatic
16
lower spo
16
age groups
16
symptomatic group
12
temperature compared
12
group lower
12

Similar Publications

Perennial grasses' reproductive phenology profoundly impacts plant morphogenesis, biomass production, and perenniality in natural ecosystems and cultivated grasslands. Complex interactions between vegetative and reproductive development complicate grass phenology prediction for various environments and genotypes. This work aims to analyse genetic × environment interactions effects on tiller growth and reproductive development in Three perennial ryegrass cultivars, Bronsyn, Carvalis, and Tryskal, were grown from seedling to heading under four inductive conditions.

View Article and Find Full Text PDF

A cross-sectional analysis was performed to investigate associations between environmental temperatures and injury occurrence in two professional male football (soccer) leagues. Data from seven seasons of the German Bundesliga (2142 matches) and four seasons of the Australian A-League (470 matches) were included. Injuries were collated via media reports for the Bundesliga and via team staff reports in the A-League and comprised injury incidence, mechanisms (contact, noncontact), locations (e.

View Article and Find Full Text PDF

This study aims to determine and compare the reference values of the haematological and biochemical blood parameters of two fish species collected from the Gökova Bay (Muğla, South-Western of Türkiye): the non-native and invasive Randall's threadfin bream, and the native Common pandora, . Both species inhabit the same environment and compete for resources. Blood samples were collected from a total of 100 fish samples (50 and 50 ) which were caught from a depth of 30 to 60 meters between February 2023 and July 2024.

View Article and Find Full Text PDF

Enhanced ensemble learning-based uncertainty and sensitivity analysis of ventilation rate in a novel radiative cooling building.

Heliyon

January 2025

Department of Energy System Engineering, Faculty of Mechanical Engineering, K.N. Toosi University of Technology, No. 15, Pardis St., Molasadra Ave., Vanak Sq., Tehran, Iran.

The rising global demand for air conditioning systems, driven by increasing temperatures and urbanization, has led to higher energy consumption and greenhouse gas emissions. HVAC systems, particularly AC, account for nearly half of building energy use, highlighting the need for efficient cooling solutions. Passive cooling, especially radiative cooling, offers potential to reduce cooling loads and improve energy efficiency.

View Article and Find Full Text PDF

The effect of thermoelectric craniocerebral cooling device on protecting brain functions in post-cardiac arrest syndrome.

Front Cardiovasc Med

January 2025

Department of Anesthesiology and Reanimation, Faculty of Medicine, Bezmialem Vakif University, Istanbul, Türkiye.

Aim: This study aimed to protect brain functions in patients who experienced in-hospital cardiac arrest through the application of local cerebral hypothermia. By utilizing a specialized thermal hypothermia device, this approach sought to mitigate ischemic brain injury associated with post-cardiac arrest syndrome, enhance survival rates, and improve neurological outcomes as measured by standardized scales.

Methods: A prospective, single-center cohort study was conducted involving patients aged ≥18 years who experienced in-hospital cardiac arrest and achieved return of spontaneous circulation (ROSC).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!