Visual prostheses provide promising solution to the blind through partial restoration of their vision via electrical stimulation of the visual system. However, there are some challenges that hinder the ability of subjects implanted with visual prostheses to correctly identify an object. One of these challenges is electrode dropout; the malfunction of some electrodes resulting in consistently dark phosphenes. In this paper, we propose a dropout handling algorithm for better and faster identification of objects. In this algorithm, phosphenes representing the object are translated to another location within the same image that has the minimum number of dropouts. Using simulated prosthetic vision, experiments were conducted to test the efficacy of our proposed algorithm. Electrode dropout rates of 10%, 20% and 30% were examined. Our results demonstrate significant increase in the object recognition accuracy, reduction in the recognition time and increase in the recognition confidence level using the proposed approach compared to presenting the images without dropout handling.Clinical Relevance- These results demonstrate the utility of dropout handling in enhancing the perception of images in prosthetic vision.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1109/EMBC46164.2021.9630991 | DOI Listing |
Front Neurorobot
December 2024
State Key Laboratory of Robotics, Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang, China.
Non-invasive brain-computer interfaces (BCI) hold great promise in the field of neurorehabilitation. They are easy to use and do not require surgery, particularly in the area of motor imagery electroencephalography (EEG). However, motor imagery EEG signals often have a low signal-to-noise ratio and limited spatial and temporal resolution.
View Article and Find Full Text PDFPLoS One
October 2024
Specialist Physician, Anesthesiology Service, Pain Unit, Complejo Asistencial Universitario de Salamanca, Salamanca, Spain (CAUSA).
ACS Appl Mater Interfaces
April 2024
State Key Laboratory of ASIC & System, School of Microelectronics, Fudan University, Shanghai 200433, China.
A switching-type power converter providing an accurate and stable switching output voltage against line/load variations and power supply ripple is mostly complicated in system-on-chip power management integrated circuits (PMICs) within a limited occupation area. Here we fabricated domain wall (DW) nanodevices using an X-cut LiNbO thin film on silicon. The domain switching event occurs after a delay time predicted by Merz's law under the applied voltage.
View Article and Find Full Text PDFCochrane Database Syst Rev
March 2024
Chair of Epidemiology and Preventive Medicine, Department of Hygiene and Dietetics, Jagiellonian University Medical College, Krakow, Poland.
Background: Liver metastases (i.e. secondary hepatic malignancies) are significantly more common than primary liver cancer.
View Article and Find Full Text PDFAdv Mater
May 2024
Institute of Molecular Aggregation Science, Tianjin University, Tianjin, 300072, China.
Compared with conventional inorganic materials, organic electrodes are competitive candidates for secondary battery cathodes due to their resourcefulness, environmental friendliness, and cost-effectiveness. Much effort is devoted at the level of chemical structure, while ignoring the impact of molecular aggregation on battery behavior. Herein, this work designs a series of organic molecules with two electrochemically active phenothiazine groups linked by different lengths of alkyl chain to regulate molecular symmetry and crystallinity.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!