Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The concept of a portable, wearable system for repetitive transcranial stimulation (rTMS) has attracted widespread attention, but significant power and field intensity requirements remain a key challenge. Here, a circuit topology is described that significantly increases induced electric field intensity over that attainable with similar current levels and coils in conventional rTMS systems. The resultant electric field is essentially monophasic, and has a controllable, shortened duration. The system is demonstrated in a compact circuit implementation for which an electric field of 94 V/m at a depth of 2 cm is measured (147 V/m at 1 cm depth) with a power supply voltage of 80 V, a maximum current of 500 A, and an effective pulse duration (half amplitude width) of 7 µsec. The peak electric field is on the same order as that of commercially available systems at full power and comparable depths. An electric field boost of 5x is demonstrated in comparison with our system operated conventionally, employing a 70 µsec rise time. It is shown that the power requirements for rTMS systems depend on the square of the product of electric field Ep and pulse duration tp, and that the proposed circuit technique enables continuous variation and optimization of the tradeoff between Ep and tp. It is shown that the electric field induced in a medium such as the human brain cortex at a specific depth is proportional to the voltage generated in a given loop of the generating coil, which allows insights into techniques for its optimization. This rTMS electric field enhancement strategy, termed 'boost rTMS (rbTMS)' is expected to increase the effectiveness of neural stimulation, and allow greater flexibility in the design of portable rTMS power systems.Clinical Relevance- This study aims to facilitate a compact, battery-powered rTMS prototype with enhanced electric field which will permit broader and more convenient rTMS treatment at home, in a small clinic, vessel, or field hospital, and potentially, on an ambulatory basis.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1109/EMBC46164.2021.9631054 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!