The spatiotemporal kinematic synergy, a coupling of multiple degrees of freedom (DoF), runs through human activities of daily living (ADL). And it is an entry point for exploring the central nervous system's (CNS) control process of musculoskeletal system by analyzing the time-varying kinematic synergy. The aim of this study was to find more physiological properties from the angular velocity profiles of synergy. Ten healthy right-handed subjects were asked to reach target button at different locations. During reaching movement, the motion data of five right upper limb joints were recorded, and the synergistic patterns were extracted by PCA algorithm. Our results showed that the combinations of the first four synergies were sufficient to explain raw data. As far as possible to exclude the effects of individual and information differences, we found shoulder flexion/extension and elbow flexion/extension made distinct contribution in a period of time to the control procedure performed by CNS after targets were confirmed. Our preliminary results implied that reaching movements required comparatively constant scheduling of shoulder horizontal abduction/adduction, shoulder internal/external rotation and wrist ulnar/radial deviation by CNS, while scheduling of SFE and EFE depends on the objectives.Clinical relevance- The findings of this paper may provide a novel dynamic control evidence based on CNS for realizing near-natural control of assistive devices in motor rehabilitation area.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1109/EMBC46164.2021.9630305 | DOI Listing |
Curr Med Imaging
January 2025
Department of Radiology, Beijing Friendship Hospital, Capital Medical University, No. 95, Yong An Road, Xicheng District, Beijing 100050, China.
Background: The neuroanatomical basis of white matter fiber tracts in gait impairments in individuals suffering from Parkinson's Disease (PD) is unclear.
Methods: Twenty-four individuals living with PD and 29 Healthy Controls (HCs) were included. For each participant, two-shell High Angular Resolution Diffusion Imaging (HARDI) and high-resolution 3D structural images were acquired using the 3T MRI.
We introduce a novel, to the best of our knowledge, method to achieve a highly efficient nonreciprocal magnon laser within a spinning cavity optomagnonic system, which integrates a magnon mode and two optical modes. The rotation of the YIG sphere triggers the Barnett effect in the magnon mode and the Sagnac effect in the optical modes. The directional input of a pump light leads to opposite Sagnac-Fizeau frequency shifts in these modes.
View Article and Find Full Text PDFExp Gerontol
January 2025
Research Group in Prevention and Health in Exercise and Sport (PHES), University of Valencia, Valencia, Spain.
Purpose: This study aimed to explore the association and prediction of hip abduction-adduction and knee flexion-extension isokinetic absolute and relative strength and power at 60°/s and 180°/s from functional tests performance (i.e., Up-and-Go Test [seconds], 30-Second Chair Stand Test [repetitions and relative and allometric power], 30-Second Arm Curl Test [repetitions], and 6-Minute Walk Test [meters]) in older adults.
View Article and Find Full Text PDFSci Rep
January 2025
Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang, 110016, China.
To achieve rapid and stable detumbling of a space noncooperative satellite, an adaptive variable admittance control method for the manipulator is proposed and verified through simulation study and the ground experiment. The control block diagram of the proposed method is presented, and the adaptive variable admittance compliant detumbling control model is established. The proposed controller includes the fixed admittance controller in manipulator task space, the adaptive pose compensator for the grasping point on docking ring, and the damping adaptive regulator based on manipulator joint angular velocity, and the stability is proven by the Lyapunov method.
View Article and Find Full Text PDFPhysiol Meas
January 2025
Faculty of Sciences, University of Coimbra, Palacio de las Escuelas 3004-531, Coimbra, 3004-504, PORTUGAL.
Objective: The detection of arterial pulsating signals at the skin periphery with Photoplethysmography (PPG) are easily distorted by motion artifacts. This work explores the alternatives to the aid of PPG reconstruction with movement sensors (accelerometer and/or gyroscope) which to date have demonstrated the best pulsating signal reconstruction.
Approach: A generative adversarial network with fully connected layers (FC-GAN) is proposed for the reconstruction of distorted PPG signals.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!