Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Seated stability is a major concern of individuals with trunk paralysis. Trunk paralysis is commonly caused by spinal cord injuries (SCI) at or above the thoracic spine. Current methods to improve stability restrict the movement of the user by constraining their trunk to an upright position. Feedback control of functional neuromuscular stimulation (FNS) can help maintain seated stability while still allowing the user to perform movements to accomplish functional tasks. In this study, an individual with a SCI (C7, AIS B) and an implanted stimulator capable of recruiting trunk and hip musculature unilaterally moved a weighted jar on a countertop to and from three prescribed stations directly in front, laterally, and across midline. For comparison, the tasks were performed with constant baseline stimulation and with feedback modulated stimulation based on the tilt of the trunk obtained from an external accelerometer fed into two PID controllers; one for forward trunk pitch and the other for lateral roll. The trunk pitch and roll angles were obtained through motion capture cameras and various measures of postural sway (95% fitted ellipse area, root mean squared (RMS), path length) and the repeatability (coefficient of variation (CoV), variance ratio (VR)) were calculated. Feedback control significantly increased RMS of trunk movement along the major axis of the fitted ellipse, but decreased RMS values during bending along the minor axis of motion. As a result, the fitted ellipse area decreased when deploying the jar to one of the stations and increased with the other two. The CoV indicated reduced variation in the presence of feedback controlled stimulation for all stations, and VR showed higher repeatability in trunk pitch. Plots of the trunk pitch and roll revealed a faster return to upright motion due to feedback stimulation.Clinical relevance- Feedback control in combination with FNS is a viable method to improve seated stability while still allowing dynamic movements in individuals with a SCI, thus addressing a major concern of the population.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1109/EMBC46164.2021.9629582 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!