A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

On Lightmyography: A New Muscle Machine Interfacing Method for Decoding Human Intention and Motion. | LitMetric

Recognising and classifying human hand gestures is important for effective communication between humans and machines in applications such as human-robot interaction, human to robot skill transfer, and control of prosthetic devices. Although there are already many interfaces that enable decoding of the intention and action of humans, they are either bulky or they rely on techniques that need careful positioning of the sensors, causing inconvenience when the system needs to be used in real-life scenarios and environments. Moreover, electromyography (EMG), which is the most commonly used technique, captures EMG signals that have a nonlinear relationship with the human intention and motion. In this work, we present lightmyography (LMG) a new muscle machine interfacing method for decoding human intention and motion. Lightmyography utilizes light propagation through elastic media and the change of light luminosity to detect silicone deformation. Lightmyography is similar to forcemyography in the sense that they both record muscular contractions through skin displacements. In order to experimentally validate the efficiency of the proposed method, we designed an interface consisting of five LMG sensors to perform gesture classification experiments. Using this device, we were able to accurately detect a series of different hand postures and gestures. We also compared LMG data with processed EMG data.

Download full-text PDF

Source
http://dx.doi.org/10.1109/EMBC46164.2021.9630177DOI Listing

Publication Analysis

Top Keywords

human intention
12
intention motion
12
muscle machine
8
machine interfacing
8
interfacing method
8
method decoding
8
decoding human
8
human
5
lightmyography
4
lightmyography muscle
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!