Patients undergoing mechanical lung ventilation are at risk of lung injury. A noninvasive bedside lung monitor may benefit these patients. The Inspired Sinewave Test (IST) can measure cardio-pulmonary parameters noninvasively. We propose a lung simulation to improve the measurement of pulmonary blood flow using IST. The new method was applied to 12 pigs' data before lung injury (control) and after lung injury (ARDS model). Results using the lung simulation shown improvements in correlation in both simulated data (R increased from 0.98 to 1) and pigs' data (R increased from <0.001 to 0.26). Paired blood flow measurements were performed by both the IST (noninvasive) and thermodilution (invasive). In the control group, the bias of the two methods was negligible (0.02L/min), and the limit of agreement was from -1.20 to 1.18 L/min. The bias was -0.68 L/min in the ARDS group and with a broader limit of agreement (-2.49 to 1.13 L/min).Clinical Relevance- the inspired sinewave test can be used to measure cardiac output noninvasively in mechanically ventilated subjects with and without acute respiratory distress syndrome.

Download full-text PDF

Source
http://dx.doi.org/10.1109/EMBC46164.2021.9630893DOI Listing

Publication Analysis

Top Keywords

lung simulation
12
lung injury
12
lung
8
pulmonary blood
8
blood flow
8
pigs' data
8
data increased
8
simulation support
4
support non-invasive
4
non-invasive pulmonary
4

Similar Publications

Simulated low-dose dark-field radiography for detection of COVID-19 pneumonia.

PLoS One

December 2024

Chair of Biomedical Physics, Department of Physics & School of Natural Sciences, Technical University of Munich, Garching bei München, Germany.

Background: Dark-field radiography has been proven to be a promising tool for the assessment of various lung diseases.

Purpose: To evaluate the potential of dose reduction in dark-field chest radiography for the detection of the Coronavirus SARS-CoV-2 (COVID-19) pneumonia.

Materials And Methods: Patients aged at least 18 years with a medically indicated chest computed tomography scan (CT scan) were screened for participation in a prospective study between October 2018 and December 2020.

View Article and Find Full Text PDF

We present a patient treated with personalized ultra-fractionated stereotactic adaptive radiotherapy (PULSAR) for non-small cell lung cancer (NSCLC) using the adaptive Varian Ethos™ system equipped with the novel HyperSight imaging platform. Three pulses of 12 Gy were separated by a pause of four weeks during which the tumor was given enough time to respond to treatment. Only initial planning computed tomography (CT) was acquired on a CT simulator (Siemens Somatom Definition Edge), whereas other pulses were adapted using online cone beam computed tomography (CBCT) images (iCBCT Acuros reconstruction) acquired while the patient was lying on the treatment couch and delivered immediately.

View Article and Find Full Text PDF

The medicinal and commercial value of pomegranate peel is attributed to its rich content of phenolic compounds, yet little is known about their concentrations and biological activity across different ripening stages. Pomegranate peels at different growth stages 1-3 (40, 80, and 120 days after fruit appearance respectively) were collected, dried, and macerated with 90% methanol. Stage 2 and stage 3 extract showed significant antimicrobial activity against , and .

View Article and Find Full Text PDF

To investigate the feasibility of non-invasively estimating the arterial partial pressure of carbon dioxide (PaCO) using a computational Adaptive Neuro-Fuzzy Inference System (ANFIS) model fed by noninvasive volumetric capnography (VCap) parameters. In 14 lung-lavaged pigs, we continuously measured PaCO with an optical intravascular catheter and VCap on a breath-by-breath basis. Animals were mechanically ventilated with fixed settings and subjected to 0 to 22 cmHO of positive end-expiratory pressure steps.

View Article and Find Full Text PDF

Time-dependent prognostic accuracy measures for recurrent event data.

Biometrics

October 2024

Evidence Generation and Advanced Analytics Biogen Digital Health, Biogen, Cambridge, MA 02142, United States.

In many clinical contexts, the event of interest could occur multiple times for the same patient. Considerable advancement has been made on developing recurrent event models based on or that use biomarker information. However, less attention has been given to evaluating the prognostic accuracy of a biomarker or a composite score obtained from a fitted recurrent event-rate model.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!