Simulation of the peel of hydrogels with stiff backing.

Soft Matter

Soft Mechanics Lab, Department of Mechanics and Aerospace Engineering, Southern University of Science and Technology, Shenzhen, 518055, China.

Published: January 2022

In this work, the peel of hydrogels under a stiff backing constraint was studied using a finite element method. The finite element method was first validated by comparing the simulation results to theoretical predictions and experimental measurements. Then, the method was used to investigate the effects of adhesion thickness, adhesion length and backing thickness on the peel behaviors, as well as the stress distribution within the adhesion layer. The results indicated that the peel force-displacement curve has a constant profile when the adhesion thickness and backing thickness are prescribed so long as the adhesion length is sufficiently long. The peak peel force increases with the adhesion length and then plateaus. The larger the intrinsic peak stress or the thicker the backing, the higher the plateau. The steady-state peel force is independent of the backing thickness, while positively correlated with the strain energy storage of the hydrogel adhesion layer. The critical vertical displacement corresponding to the peak peel force increases with the hydrogel thickness and decreases with the backing thickness. However, the critical vertical displacement corresponding to the steady-state peel force increases with the backing thickness. The present work puts forward an effective numerical approach to probe the peel of hydrogels, which is beneficial for the design of relevant structures.

Download full-text PDF

Source
http://dx.doi.org/10.1039/d1sm01383aDOI Listing

Publication Analysis

Top Keywords

backing thickness
20
peel force
16
peel hydrogels
12
adhesion length
12
force increases
12
hydrogels stiff
8
backing
8
stiff backing
8
peel
8
finite element
8

Similar Publications

This paper presents a novel adaptive fault-tolerant control (AFTC) framework for systems with piezoelectric sensor patches, specifically targeting sensor faults and external disturbances. The proposed method ensures robust control of cantilever thick plates by integrating adaptive estimation to simultaneously handle sensor faults and system uncertainties, maintaining stability despite issues like drift, bias, loss of accuracy, and effectiveness. Unlike traditional approaches that address sensor faults individually, our method provides a comprehensive solution backed by Lyapunov-based stability analysis, demonstrating uniform ultimate boundedness under various fault conditions.

View Article and Find Full Text PDF

Ultrasound is an excellent way to acquire data that reveal useful information about systems operating in harsh environments, which may include elevated temperature, ionizing radiation, and aggressive chemicals. The effects of harsh environments on piezoelectric materials have been studied in much more depth than the other aspects of ultrasonic transducers used in pulse-echo mode. Therefore, finite element simulations and laboratory experiments are used to demonstrate the unique characteristics of pulse-echo immersion testing.

View Article and Find Full Text PDF

Past work has considered the analytic properties of the reflection coefficient for a metal-backed slab. The primary result established a fundamental relationship for the minimal layer thickness to bandwidth ratio achievable for an absorber. There has yet to be establishment of a similar relationship for non-metal-backed layers, and here we present the universal result based on the Kramers-Kronig relations.

View Article and Find Full Text PDF

Composite polymer membranes were obtained using the so-called dry phase inversion and were used for desalination of diluted saline water solutions by pervaporation (PV) method. The tests used a two-layer backing, porous, ultrafiltration commercial membrane (PS20), which consisted of a supporting polyester layer and an active polysulfone layer. The active layer of PV membranes was obtained in an aqueous environment, in the presence of a surfactant, by cross-linking a 5 wt.

View Article and Find Full Text PDF

Convertible glenoid replacement in the anatomical total shoulder arthroplasty: medium-term results.

Arch Orthop Trauma Surg

September 2024

Shoulder Centre, Sports Traumatology Prof. Habermeyer, Törringstrasse 6, 81675, Munich, Germany.

Article Synopsis
  • The study aimed to evaluate the medium-term clinical and radiological outcomes of a new thinner metal-backed glenoid prosthesis, addressing high failure rates of older versions.
  • Thirty-nine patients with specific shoulder conditions were analyzed over a follow-up period of 2 to 10 years, where significant improvement in shoulder function was noted following surgery.
  • While some radiological issues were observed, such as osteolysis and humeral migration, overall results showed promising enhancement in function and satisfaction among patients.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!