Innovations in syringe and pen needle (PN) technology over the last 100 years have led to important advances in insulin delivery for people with diabetes, paralleling the strides made in developing recombinant DNA human insulin and insulin analogs with varying onset and duration of action. In this review, the history of advances in insulin delivery is described, focusing on progress in syringe, needle, and PN technologies. The early glass and metal syringes that required sterilization by boiling have been replaced by disposable, single-use syringes or pens with clear labeling for precise insulin dosing. The early needles ranging in length from 19 to 26 mm that required manual sharpening against a whetstone have been replaced by syringe needles of 6 mm and PNs of 4 mm in length as slender as 34 gauge. Imaging studies using ultrasound and computed tomography measured the thickness of skin and subcutaneous tissue layers to show feasibility of targeted insulin administration with shorter needles. These developments, coupled with innovations in needle/PN wall and tip structure, have led to improved injection experience for people with diabetes. It is also important to acknowledge the role of injection technique education, together with these advances in injection technology, for improving clinical outcomes and patient satisfaction. With continued projected growth of diabetes prevalence, particularly in developing countries where expensive and complex insulin delivery systems may not be practical, insulin syringes and pens will continue to serve as reliable and cost-effective means of insulin delivery for people with diabetes.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10012366PMC
http://dx.doi.org/10.1177/19322968211059564DOI Listing

Publication Analysis

Top Keywords

insulin delivery
16
people diabetes
12
insulin
10
needle technology
8
insulin administration
8
advances insulin
8
delivery people
8
syringes pens
8
technology insulin
4
administration century
4

Similar Publications

The purpose of this study is to examine the pregestational BMI value that results in insulin use in Japanese patients with gestational diabetes mellitus (GDM) and to assess whether the type of GDM treatment affects postpartum glucose tolerance. This retrospective study included 21 GDM patients treated until parturition at our department from 2013 to 2017. We calculated the pregestational BMI related to insulin treatment and the significant elevation in homeostasis model assessment of insulin resistance (HOMA-IR) by receiver operating characteristics curve (ROC) analysis.

View Article and Find Full Text PDF

Level of Satisfaction Among Patients Using Insulin Administered by Pen vs Vial/Syringe. An Observational Prospective Study.

Patient Prefer Adherence

January 2025

Grupo de Investigación en Farmacoepidemiología y Farmacovigilancia, Universidad Tecnológica de Pereira-Audifarma S.A, Pereira, Risaralda, Colombia.

Purpose: To determine the satisfaction of patients with diabetes mellitus who used subcutaneous insulin application devices in Colombia.

Patients And Methods: An observational prospective study of patients with diabetes mellitus receiving insulin treatment in Colombia. Sociodemographic, comorbidity and pharmacological data were taken from a drug dispensing database.

View Article and Find Full Text PDF

Introduction: This analysis aimed to investigate diabetes-specific psychological outcomes among adults with type 1 diabetes (T1D) using hybrid closed-loop (HCL) versus standard therapy.

Research Design And Methods: In this multicenter, open-label, randomized, controlled, parallel-group clinical trial, adults with T1D were allocated to 26 weeks of HCL (MiniMed™ 670G) or standard therapy (insulin pump or multiple daily injections without real-time continuous glucose monitoring). Psychological outcomes (awareness and fear of hypoglycemia; and diabetes-specific positive well-being, diabetes distress, diabetes treatment satisfaction, and diabetes-specific quality of life (QoL)) were measured at enrollment, mid-trial and end-trial.

View Article and Find Full Text PDF

Objectives: Gestational diabetes mellitus (GDM) is associated with an increased risk of both neonatal and maternal morbidity. The aim of this retrospective study was to evaluate the frequency of perinatal complications due to GDM in the Department of Neonatology at the Medical University of Wroclaw, Poland, considering the treatment of GDM-diet and physical activity versus insulin therapy. The influence of maternal comorbidities and the COVID-19 pandemic on pregnancy outcomes was assessed.

View Article and Find Full Text PDF

Objective: The objective of this study was to explore the possibility of treating heart failure in rats by delivering mRNA of 24-dehydrocholesterol reductase (DHCR24) into the body through lipid nanoparticles (LNPs).

Methods: We established a heart failure rat model using doxorubicin. The experiment was divided into blank, model, mRNA stock solution cardiac injection, mRNA stock solution intravenous injection, LNP-mRNA stock solution cardiac injection, and LNP-mRNA stock solution intravenous injection groups.

View Article and Find Full Text PDF