Successful Implantation of a Leadless Pacemaker in a Patient With a Tricuspid Clip.

CJC Open

Southlake Regional Health Centre, University of Toronto, Newmarket, Ontario, Canada.

Published: October 2021

Leadless pacemakers have become an effective alternative to conventional transvenous pacemakers to prevent the risk of lead failure, pocket complications, and iatrogenic tricuspid regurgitation. The current transcatheter approach for tricuspid valve repair can limit the implantation of these devices, unless the procedure is performed with appropriate image guidance. We present the case of a patient with severe tricuspid regurgitation secondary to pacemaker lead impingement who, despite the implantation of a tricuspid clip, received a leadless pacemaker. The procedure was successfully guided by transthoracic echocardiography, an alternative to transesophageal or intracardiac echocardiography.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8636233PMC
http://dx.doi.org/10.1016/j.cjco.2021.05.014DOI Listing

Publication Analysis

Top Keywords

leadless pacemaker
8
tricuspid clip
8
tricuspid regurgitation
8
tricuspid
5
successful implantation
4
implantation leadless
4
pacemaker patient
4
patient tricuspid
4
clip leadless
4
leadless pacemakers
4

Similar Publications

Background: Transvenous pacemakers (TVP) and leadless pacemakers (LP) are two reliable permanent modalities for the treatment of heart rhythm disorders. Several observational studies explored the safety and efficacy of the two devices. The aim of this meta-analysis study is to present a comparative analysis of the safety of leadless versus transvenous pacemakers.

View Article and Find Full Text PDF

Background: The adoption of leadless pacemakers (LPMs) is increasing, yet the impact of body mass index (BMI) on procedural outcomes remains underexplored.

Objective: The purpose of this study was to explore the impact of BMI on in-hospital outcomes for patients receiving LPM implantation.

Methods: Data from the National Inpatient Sample from 2018-2021 were analyzed for patients older than 18 years who underwent LPM implantation, with specific inclusion and exclusion criteria applied.

View Article and Find Full Text PDF

Leadless pacemakers (LPs) are emerging options for bradyarrhythmias. However, extraction can be risky if the device is in an unfavorable position. We present a challenging case of a Nanostim LP (NLP) (Abbott Medical Inc.

View Article and Find Full Text PDF

3D computed tomography integration guiding permanent Aveir AR leadless pacemaker implantation: a case report.

Eur Heart J Case Rep

January 2025

AL Qassimi Hospital, Emirates Health Services (EHS), Wasit Street-Al khazamiya, Sharjah 3500, United Arab Emirates.

Background: The use of single-chamber, right ventricular (RV) leadless pacemakers (LPs) has been well established, the introduction of a right atrial LPs has opened the door for dual-chamber leadless pacing. Cardiac computed tomography (CT) segmentation integration might provide proper visual guide during the procedure.

Case Summary: A 58-year-old male patient was brought to the emergency department with dizziness and complete heart block.

View Article and Find Full Text PDF

Modular Leadless Pacing: A Case Series of Leadless Pacemaker Upgrades.

JACC Clin Electrophysiol

December 2024

Division of Cardiology, Department of Medicine, Weill Cornell Medicine, New York-Presbyterian Hospital, New York, New York, USA. Electronic address:

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!