Background: Kyphosis in spondylitis tuberculosis (STb) is more than just a cosmetic issue. It has a potentially detrimental effect on both spine-associated structures and cardiopulmonary function. It can be corrected in any stage of STb; however, the corrective surgery is challenging, especially in the late case, in which the additional stiffness of the spine can come into consideration. To date, the cantilever technique is still a gold standard for sagittal plane deformity correction. However, no study to date has explored its effectiveness for thoracolumbar kyphotic deformity, especially that caused by spondylitis tuberculosis.

Methods: This is a retrospective study of 16 consecutive cases of spondylitis tuberculosis with thoracolumbar kyphosis that underwent corrective surgery in our center in the period of 2020-2021. We aim to evaluate the effectiveness of the cantilever technique that we use for kyphotic correction in thoracolumbar STb patients.

Results: At the 3-months follow-up, the mean Cobb angle was 14.6°±10.27°, with the mean gain of 20.90°±12.00° and positively correlate with the thoracolumbar kyphosis (TLK) correction (68.69%, r = 0.654, p = 0.001). The mean thoracic kyphosis, lumbar lordosis, and sagittal vertebral axis were 30.6°±13.08°, 39.4°±16.02°, and 1.4±4.09 cm, respectively, with sagittal Cobb difference of 12.70±9.85.

Conclusion: The kyphotic Cobb angle reduction by cantilever technique in the thoracolumbar area significantly improved the thoracolumbar kyphosis and realign the spinal sagittal axis. Thus, the cantilever technique remains the gold standard for sagittal plane deformity correction which can be applied for kyphotic deformity correction in thoracolumbar STb cases.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8651210PMC
http://dx.doi.org/10.2147/ORR.S342365DOI Listing

Publication Analysis

Top Keywords

cantilever technique
16
spondylitis tuberculosis
12
deformity correction
12
thoracolumbar kyphosis
12
reduction cantilever
8
thoracolumbar
8
corrective surgery
8
gold standard
8
standard sagittal
8
sagittal plane
8

Similar Publications

Finite element analysis of stress distribution in cantilever resin-bonded zirconia fixed dental prosthesis and periodontal tissue with alveolar bone loss.

J Prosthodont Res

January 2025

Department of Masticatory Function and Health Science, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), Tokyo, Japan.

Purpose: To compare the stress distribution in loaded zirconia resin-bonded fixed dental prostheses (RBFDPs) and periodontal tissue using finite element analysis, considering reduced alveolar bone levels and the number of retainers.

Methods: A human skull was micro-CT scanned. Three framework designs were tested: a 2-unit RBFDP using the maxillary left central incisor (#21) as an abutment, another using a canine (#23), and a 3-unit RBFDP using both #21 and #23.

View Article and Find Full Text PDF

Cantilever-Enhanced Fiber-Optic Photoacoustic Spectrophone for Low-Pressure Gas Detection.

Anal Chem

January 2025

School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian 116024, Liaoning, China.

A cantilever-enhanced fiber-optic photoacoustic (PA) spectrophone is reported for trace gas detection at a low-pressure environment. A cantilever-based fiber-optic Fabry-Perot (F-P) interferometer (FPI) is utilized for simultaneous measurement of air pressure and PA pressure. Since the cantilever resonance frequency follows air pressure linearly, the fundamental frequency intensity modulation (1-IM) technique is applied to scan the frequency response of the solid PA signal from tube wall absorption for tracking the cantilever resonance frequency in real time.

View Article and Find Full Text PDF

Atomic Force Microscopy of Viruses.

Subcell Biochem

December 2024

Department of Physics of the Condensed Matter, C03 and IFIMAC (Instituto de Física de la Materia Condensada). Universidad Autónoma de Madrid, Madrid, Spain.

Atomic force microscopy (AFM) makes it possible to obtain images at nanometric resolution, and to accomplish the manipulation and physical characterization of specimens, including the determination of their mechanical and electrostatic properties. AFM has an ample range of applications, from materials science to biology. The specimen, supported on a solid surface, can be imaged and manipulated while working in air, ultra-high vacuum or, most importantly for virus studies, in liquid.

View Article and Find Full Text PDF

Background: Determining the distal cantilever length in All-on-Four (All-on-4) implant-supported prostheses is a major factor in the long-term success of these prostheses. The difference in mechanical properties of materials used in the fabrication of these prostheses, such as polyether ether ketone (PEEK), may have an impact on the determination of the cantilever length that best distributes stress.

Aim: To study the distribution of stress in All-on-4 mandibular prostheses in the bone, implants, and framework according to difference cantilever length in PEEK prosthetic framework using three-dimensional finite element analysis.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to evaluate the biomechanical properties of SutureTape as an alternative technique for arthrodesis of the metacarpophalangeal (MCP) and proximal interphalangeal (PIP) joint arthrodesis when compared with surgical steel wire.

Methods: A total of 32 fingers (index, long, ring, and small) from two matched pair cadaveric hands were used. K-wire and surgical steel wire were used for MCP and PIP joint arthrodesis of the control group (group I), whereas K-wire and SutureTape were used for the experimental group (group II).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?