Shape reconstruction is growing as an important real-time monitoring strategy for applications that require rigorous control. Polymer optical fiber sensors (POF) have mechanical properties that allow the measurement of large curvatures, making them appropriate for shape sensing. They are also lightweight, compact and chemically stable, meaning they are easy to install and safer in risky environments. This paper presents a sensor system to detect angles in multiple planes using a POF-intensity-variation-based sensor and a procedure to detect the angular position in different planes. Simulations are performed to demonstrate the correlation between the sensor's mechanical bending response and their optical response. Cyclic flexion experiments are performed at three test frequencies to obtain the sensitivities and the calibration curves of the sensor at different angular positions of the lateral section. A Fast Fourier Transform (FFT) analysis is tested as a method to estimate angular velocities using POF sensors. The experimental results show that the prototype had high repeatability since its sensitivity was similar using different test frequencies at the same lateral section position. The proposed approach proved itself feasible considering that all linear calibration curves presented a coefficient of determination (R2) higher than 0.9.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8659952PMC
http://dx.doi.org/10.3390/s21237848DOI Listing

Publication Analysis

Top Keywords

shape sensing
8
polymer optical
8
test frequencies
8
calibration curves
8
influence two-plane
4
two-plane position
4
position stress
4
stress intensity-variation-based
4
intensity-variation-based sensors
4
sensors shape
4

Similar Publications

Living with acuteness in chronic illness: The temporal underpinnings of endometriosis.

Med Anthropol Q

December 2024

Helsinki Collegium for Advanced Studies, University of Helsinki, Helsinki, Finland.

This article explores how acuteness is experienced by people with endometriosis in Finland. Drawing on in-depth interviews as well as anonymous written endometriosis stories, we trace instances when the sense of chronicity and cyclicality of endometriosis is disrupted by a possibility of risk to life. These instances include when endometriosis tissue grows in unanticipated and aggressive ways, when medical interventions lead to unexpected complications or medications raise concerns about a gradually developing risk, and when endometriosis diagnosis becomes a catch-all category that could mask the onset of a life-threatening condition.

View Article and Find Full Text PDF

Mirror-invariance is not exclusively visual but extends to touch.

Sci Rep

December 2024

Department of Psychology, Jagiellonian University, ul. Ingardena 6, 30-060, Kraków, Poland.

Mirror-invariance enables recognition of mirrored objects as identical. During reading acquisition, sighted readers must overcome this innate bias to distinguish between mirror-inverted letters ('d' vs. 'b').

View Article and Find Full Text PDF

Expression of Yes-associated protein in endothelial cells of human corneas before and after storage in organ culture.

Sci Rep

December 2024

Laboratory of Biology, Engineering, and Imaging for Ophthalmology, BiiO, Faculty of Medicine, University of Jean Monnet, 10 rue de la Marandière, 42270, Saint-Priest en Jarez, France.

The cornea, the anterior meniscus-shaped transparent and refractive structure of the eyeball, is the first mechanical barrier of the eye. Its functionality heavily relies on the health of its endothelium, its most posterior layer. The treatment of corneal endothelial cells (CECs) deficiency is allogeneic corneal graft using stored donor corneas.

View Article and Find Full Text PDF

The ground-based solar telescope THEMIS performed several observations of Mercury's sodium exosphere in years 2011-2013, when the MESSENGER spacecraft was orbiting around the planet. Typical two-peak exospheric patterns were frequently identified. In previous studies, some specific cases of THEMIS Na two-peak observations were characterized and related to IMF conditions, during specific extreme cases, in the occasion of CME arrival.

View Article and Find Full Text PDF

The detectability size threshold of visible particles (″visibility″ size) in the context of visual inspection of parenteral drug products has been an elusive target for several decades. The current common sense, also reflected in official guidelines, dictates that particles of different shapes and morphologies have different ″visibility″ size thresholds, that can range between hundreds and thousands of micrometers. This study demonstrates experimentally for the first time that it is possible to define a single, shape- and morphology- independent detectability size threshold, identical across particles of various types, provided that observation conditions and product attributes are kept constant.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!