Background: To evaluate the techniques, efficacy, and safety for treating vascularly inaccessible abdominal visceral pseudoaneurysms by direct puncture and embolization.
Methods: A retrospective study of 5 consecutive patients who underwent percutaneous direct puncture embolization for intra-abdominal pseudoaneurysms in our institution between January 2009 and December 2016. Technical aspects, success, clinical outcome, and complications were discussed.
Results: Four patients (80%) were men, and the mean age of all five patients was 57.2 years (range, 47-72 years). The mean diameter of the pseudoaneurysms was 2.5 cm (range, 1.9-3.4 cm). All the pseudoaneurysms were punctured under the imaging guidance of fluoroscopy, ultrasound, or computed tomography. Coils and glue were used in four of the patients, the remaining one with coil only. The mean injected glue volume was 1.5 (range, 0.8-2) mL. The overall technical and clinical success rate was 100% without major complications or mortality.
Conclusion: Our single-center experience and the literature review demonstrate that percutaneous direct puncture embolization is feasible and effective to serve as an alternative for treating abdominal vascular pseudoaneurysms when the traditional endovascular embolization fails. In this approach, fluoroscopy is the most needed guidance technique.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/JCMA.0000000000000679 | DOI Listing |
Cardiovasc Intervent Radiol
January 2025
Department of Radiology, Teikyo University School of Medicine, 2-11-1 Kaga, Itabashi-Ku, Tokyo, Japan.
Background: Lymphatic leaks are associated with significant mortality and morbidity. Intranodal lymphangiography (ILAG) involves the direct injection of ethiodised lipid into the hilum of lymph nodes. It is diagnostic procedure that can have therapeutic effects secondary to a local sclerosant effect.
View Article and Find Full Text PDFNutrients
December 2024
Bionos Biotech SL, LabAnalysis Life Science, Biopolo Hospital La Fe, 46026 Valencia, Spain.
Background/objectives: Magnesium (Mg)-based food supplements contribute to the maintenance of adequate levels of Mg that are essential for overall health and well-being. The aim of this double-blind, randomized, cross-over clinical study was to assess the plasma Mg levels in volunteers following the oral administration of a magnesium-based nutraceutical ingredient, MAGSHAPE microcapsules (Mg-MS), in comparison to other commonly used magnesium sources, including the following: Mg Oxide (MgO), Mg Citrate (Mg-C), and Mg bisglycinate (Mg-BG).
Methods: A total of 40 healthy women and men were put on a low-Mg diet for 7 days, and after 8 h of fasting, a blood sample was taken from a digital puncture before (0 h) and 1 h, 4 h, and 6 h after the oral intake of each product.
Int J Biol Macromol
January 2025
Department of Orthopedics, National Taiwan University Hospital and National Taiwan University College of Medicine, No. 1, Section 1, Jen-Ai Road, Taipei 100, Taiwan. Electronic address:
Local anesthetic (LA)-induced peripheral nerve block (PNB) is an important part of multimodal analgesia to reduce postoperative pain, accelerate postoperative recovery, and improve clinical prognosis. The duration of LA depends on anesthetics, and the repeated nerve positioning, puncture injection or indwelling catheter is often required to prolong the effect of PNB. In this study, the genipin, was used to crosslink gelatin-based hydrogel, and then co-loaded with indocyanine green (ICG) and lidocaine as an LA-controlled release system (ICG@Lido/Gel and ICG@Lido/gGel).
View Article and Find Full Text PDFRetin Cases Brief Rep
January 2025
The Retina Service of Wills Eye Hospital, Wills Eye Physicians-Mid Atlantic Retina, Thomas Jefferson University, Philadelphia, PA.
Purpose: To illustrate a technique for the removal of subretinal gas via pars plana vitrectomy (PPV) with air-fluid exchange and simultaneous manipulation with scleral depression.
Methods: PPV to remove subretinal gas causing persistent macula-off retinal detachment was performed in one eye, and the results were evaluated in this case report. Ports were carefully placed to avoid puncturing the retina, which was significantly displaced anteriorly past the ora serrata due to the buoyancy of the subretinal gas with the patient in a supine position.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!