Purpose: This study aimed to evaluate the dependability of automated breast ultrasound (ABUS) compared with handheld ultrasound (HHUS) and mammography (MG) on the Breast Imaging Reporting and Data System (BI-RADS) category and size assessment of malignant breast lesions.
Patients And Methods: A total of 344 confirmed malignant lesions were recruited. All participants underwent MG, HHUS, and ABUS examinations. Agreements on the BI-RADS category were evaluated. Lesion size assessed using the three methods was compared with the size of the pathological result as the control. Regarding the four major molecular subtypes, correlation coefficients between size on imaging and pathology were also evaluated.
Results: The agreement between ABUS and HHUS on the BI-RADS category was 86.63% (kappa = 0.77), whereas it was 32.22% (kappa = 0.10) between ABUS and MG. Imaging lesion size compared to pathologic lesion size was assessed correctly in 36.92%/52.91% (ABUS), 33.14%/48.84% (HHUS) and 33.44%/43.87% (MG), with the threshold of 3 mm/5 mm, respectively. The correlation coefficient of size of ABUS-Pathology (0.75, Spearman) was statistically higher than that of the MG-Pathology (0.58, Spearman) with P < 0.01, but not different from that of the HHUS-Pathology (0.74, Spearman) with P > 0.05. The correlation coefficient of ABUS-Pathology was statistically higher than that of MG-Pathology in the triple-negative subtype, luminal B subtype, and luminal A subtype (<0.01).
Conclusion: The agreement between ABUS and HHUS in the BI-RADS category was good, whereas that between ABUS and MG was poor. ABUS and HHUS allowed a more accurate assessment of malignant tumor size compared to MG.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8647168 | PMC |
http://dx.doi.org/10.2147/IJGM.S342567 | DOI Listing |
Diagnostics (Basel)
January 2025
Department of Radiology, Inje University Haeundae Paik Hospital, Busan 48108, Republic of Korea.
: This study aimed to compare ultrasound (US) findings between automated and handheld breast ultrasound (ABUS and HHUS, respectively) in small breast cancers, based on the breast imaging reporting and data system (BI-RADS) category. : We included 51 women (mean age: 52 years; range: 39-66 years) with breast cancer (invasive or DCIS), all of whom underwent both ABUS and HHUS. Patients with tumors measuring ≤1 cm on either modality were enrolled.
View Article and Find Full Text PDFQuant Imaging Med Surg
January 2025
Department of Radiology, The First Affiliated Hospital of Zhejiang Chinese Medical University (Zhejiang Provincial Hospital of Chinese Medicine), Hangzhou, China.
Background: Breast imaging reporting and data system (BI-RADS) provides standard descriptors but not detailed decision rules for characterizing breast lesions. Diffusion-weighted imaging (DWI) and T2-weighted imaging (T2WI) are also not incorporated in the BI-RADS. Several multiparametric magnetic resonance imaging (mpMRI)-based decision rules have been developed to differentiate breast lesions, but lack external validation.
View Article and Find Full Text PDFJ Breast Imaging
January 2025
Department of Radiology, University of Cambridge School of Clinical Medicine, Cambridge Biomedical Campus, Cambridge, UK.
Breast cancer is the most prevalent cancer in women in Europe, and while all European countries have some form of screening for breast cancer, disparities in organization and implementation exist. Breast density is a well-established risk factor for breast cancer; however, most countries in Europe do not have recommendations in place for notification of breast density or additional supplementary imaging for women with dense breasts. Various supplemental screening modalities have been investigated in Europe, and when comparing modalities, MRI has been shown to be superior in cancer detection rate and in detecting small invasive disease that may impact long-term survival, as demonstrated in the Dense Tissue and Early Breast Neoplasm Screening (DENSE) trial in the Netherlands.
View Article and Find Full Text PDFRev Esp Patol
January 2025
Department of Pathology, Vardhman Mahavir Medical College and Safdarjung Hospital, New Delhi, India. Electronic address:
Background: The diagnosis of breast cancer necessitates a multifaceted approach integrating cytopathological and radiological assessments. The International Academy of Cytology (IAC) Yokohama system and Breast Imaging Reporting and Data System (BI-RADS) are fundamental frameworks in this context. This study aims to evaluate the diagnostic potential of a combined Yokohama-BI-RADS scoring system for breast lesions.
View Article and Find Full Text PDFGland Surg
December 2024
Department of Ultrasound, The First Medical Center, Chinese PLA General Hospital, Beijing, China.
Background: Accurate diagnosis of breast cancer is of great importance to improve the prognosis of patients. Artificial intelligence (AI)-assisted diagnostic system for breast ultrasound is gradually being applied in the identification of benign and malignant breast lesions. This study aimed to evaluate the diagnostic performance and optimal application of AIassisted ultrasonography for breast lesions in clinical setting.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!