Aim: This systematic review and network meta-analysis synthesizes the available clinical evidence concerning efficacy with respect to plaque scores following a brushing action with oscillating-rotating (OR) or high-frequency sonic (HFS) powered toothbrushes (PTB) compared with a manual toothbrush (MTB) as control.
Material And Methods: Databases were searched up to 1 August 2021, for clinical trials that evaluated the efficacy of a PTB with OR or HFS technology compared with an MTB on plaque removal after a single-brushing action and conducted with healthy adult patients. Meta-analysis (MA) and a network meta-analysis (NMA) were performed.
Results: Twenty-eight eligible publications, including 56 relevant comparisons, were retrieved. The overall NMA results for the mean post-brushing score showed a statistically significant difference for the comparison between an OR PTB and an MTB (SMD = -0.43; 95% CI [-0.696;-0.171]). The change in plaque score data showed a significant effect of a PTB over an MTB and OR over HFS. Based on ranking, the OR PTB was highest, followed by the HFS PTB and the MTB.
Conclusion: Within the limitations of the present study design, based on the outcome following a single-brushing action, it can be concluded that for dental plaque removal, there is a high certainty for a small effect of a PTB over an MTB. This supports the recommendation to use a powered toothbrush for daily plaque removal. There is moderate certainty for a very small benefit for the use of a powered toothbrush with an OR over an HFS mode of action.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9303421 | PMC |
http://dx.doi.org/10.1111/idh.12563 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!