Rapid detection of a novel B1-β-lactamase gene, blaAFM-1 using a loop-mediated isothermal amplification (LAMP) assay.

Ann Clin Microbiol Antimicrob

Laboratory Medicine Center, Nanfang Hospital, Southern Medical University, Guangzhou, 510515, China.

Published: December 2021

Background: BlaAFM-1 (GenBank Accession No. 143105.1) is a new B1 subclass metallo-β-lactamase gene discovered by our group, and isolated from an Alcaligenes faecalis plasmid that renders carbapenem antibiotics ineffective. In this study, we generated a fast and reliable assay for blaAFM-1 detection.

Methods: We designed optimum loop-mediated isothermal amplification (LAMP) primers and constructed a recombinant plasmid AFM-1 to specifically detect blaAFM-1. Optimal LAMP primers were used to assess sensitivity of the recombinant plasmid AFM-1 and blaAFM-1-supplemented samples (simulated sputum and simulated feces). Fifty two samples, without blaAFM-1, were used to assess LAMP real-time assay specificity; these samples were verified by conventional PCR and sequencing for the absence of blaAFM-1. Three hundred clinical Gram-negative carbapenem-resistant strains were tested by LAMP assay for strains carrying blaAFM-1, which were confirmed by conventional PCR and Sanger sequencing. We calculated the sensitivity and its 95% confidence interval (95% CI), specificity and its 95% CI, and predictive values of the LAMP assay and conventional PCR/sequencing by investigating positive and negative clinical strains.

Results: The lowest limit of detection for the recombinant plasmid AFM-1 and blaAFM-1-supplemented samples (in both simulated sputum and simulated feces) was 10 copies/reaction. All amplification curves of the 52 blaAFM-1-free bacteria strains were negative, suggesting the LAMP assay had excellent specificity for detecting blaAFM-1. Among the 300 clinical strains, eight were positive for blaAFM-1 using LAMP. These LAMP results were consistent with conventional PCR and Sanger sequencing data. As with conventional PCR/sequencing, the LAMP method exhibits 100% sensitivity (95% CI 59.8-100%) and 100% specificity (95% CI 98.4-100%) for blaAFM-1 detection. The LAMP assay is also time-efficient (1 h) for blaAFM-1 detection.

Conclusions: We established a new LAMP assay with high sensitivity and specificity to detect the novel B1-β-lactamase gene, blaAFM-1.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8650397PMC
http://dx.doi.org/10.1186/s12941-021-00486-zDOI Listing

Publication Analysis

Top Keywords

lamp assay
24
blaafm-1
12
lamp
12
recombinant plasmid
12
plasmid afm-1
12
conventional pcr
12
novel b1-β-lactamase
8
b1-β-lactamase gene
8
gene blaafm-1
8
loop-mediated isothermal
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!