Background: Use of a porous tantalum tibial component for total knee arthroplasty (TKA) was reported to have beneficial effects on periprosthetic bone mineral density (BMD). In some cases, hexagonal peg is placed close to or in contact with the tibial cortex, which may result in stress-shielding around the peg. However, no studies have analyzed the relationship between peg position and BMD. The aim of this study was to compare the peg position and BMD around the peg in a porous tantalum tibial component after TKA.
Methods: Twenty-seven patients (27 knees) who underwent primary TKA with a cementless porous tantalum tibial component were investigated. BMD was measured by dual-energy X-ray absorptiometry for 2 years after the operation. The distance between the peg and the tibial cortex (peg distance) was measured on the medial and lateral sides.
Results: BMD was decreased in the medial region after the operation (p < 0.01). Relative change in BMD was lower in the medial region than in the central and lateral regions (p < 0.01). Multiple regression analysis showed that medial peg distance was negatively correlated with relative change of BMD in the medial part of the tibia (p = 0.04, R = 0.402).
Conclusions: The medial peg position affected the postoperative relative change of BMD in the medial part of the tibia, but did not affect the longevity of the implant. As the tibial medial peg became closer to the medial tibial cortex, the BMD loss became larger in the medial part of the tibia at 2 years postoperatively.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.knee.2021.11.005 | DOI Listing |
Sci Rep
January 2025
School of Civil Engineering, Central South University, Changsha, 410083, China.
This study investigates the deposition of tantalum (Ta) coatings on carbon foams using the chemical vapor deposition (CVD) method to enhance their compressive strength. Two types of open-cell carbon foams, CF-1 and CF-2, with different strut diameters, were examined. The morphology and uniformity of the coatings were characterized, and the effect of coating thickness on the compressive strength of the foams was systematically analyzed.
View Article and Find Full Text PDFJ Biomed Mater Res A
January 2025
Department of Orthopedics, The Third Affiliated Hospital of Chongqing Medical University, Chongqing, People's Republic of China.
Bone defects are difficult to treat clinically and most often require bone grafting for repair. However, the source of autograft bone is limited, and allograft bone carries the risk of disease transmission and immune rejection. As tissue engineering technology advances, bone replacement materials are playing an increasingly important role in the treatment of bone defects.
View Article and Find Full Text PDFJ Orthop Surg Res
December 2024
Center for Joint Surgery, Southwest Hospital, Army Medical University, Gaotanyan Street, Shapingba District, Chongqing, 400038, China.
Purpose: This study aims to investigate the suitable surgical strategies for applying TaBw01 porous tantalum rod across different stages of osteonecrosis of the femoral head (ONFH).
Methods: TaBw01 tantalum rods were fabricated using type FTaY-1 tantalum powder via the foam impregnation-sintering method. Mechanical testing with the Instron 8801 universal testing machine and finite element analysis (FEA) assessed single tantalum rod implantation and impaction bone grafting combined with rod implantation.
Langmuir
December 2024
Key Laboratory of Soft Chemistry and Functional Materials of Education Ministry, Nanjing University of Science and Technology, Nanjing 210094, China.
Traditional anodization was generally conducted in aqueous or water-containing solutions at room temperature or even lower temperatures. The two best known examples of the application of traditional anodization in the fabrication of nanostructured oxides are porous anodic alumina and titania nanotube films. In 1998, Melody et al.
View Article and Find Full Text PDFZhongguo Gu Shang
November 2024
Department of Joint Surgery, the 940th Hospital of PLA Joint Logistics Support Force, Lanzhou 730050, Gansu, China.
Objective: To explore the surgical technique and clinical outcomes of biological total hip arthroplasty(THA) combined with impacting bone grafting for the treatment of moderate to severe acetabular invagination secondary to rheumatoid arthritis(RA).
Methods: Total of 20 patients(28 hips) with RA secondary to acetabular invagination were treated with THA of bioprosthesis combined with autogenous bone grafting from January 2012 to October 2020, including 5 males(8 hips) and 15 females(20 hips) with an average age of (55.10±4.