Clinical Relevance: It is important to distinguish between visual acuity, optical quality and quality of vision when outcomes obtained with intraocular lenses are evaluated. These parameters, that includeobjective and subjective tests, should be assessed to obtain results that are not biased.
Background: To assess the difference in visual and optical quality between two monofocal intraocular lens models.
Methods: : This was a prospective, parallel and randomised clinical study conducted at Miranza IOA, a private clinic in Madrid, Spain. Sixty patients were implanted bilaterally, 30 per group, with two aspheric IOLs with induced spherical aberration of -0.27 μm for Group A and -0.20 μm for Group B. Visual outcomes obtained at 1 and 3 months after surgery included both uncorrected (UCVA) and corrected monocular distance visual acuity (DCVA), objective scattering index (OSI), modulation transfer function (MTF) cut-off, Strehl Ratio (SR), contrast sensitivity defocus curve (CSDC), intraocular lens spherical aberration (SA), and longitudinal chromatic aberration of the eye. Activity limitations in daily life were assessed using CatQuest-9SF questionnaire.
Results: There were statistically significant differences for DCVA (0.04 LogMAR; p = .008) and SR (0.03; p = .003) between groups. Outcomes related to CSDC showed statistically significant differences for vergences between -0.50 D and +1.00 D (3 mm pupil) and for vergences of 0.00 D and +0.50 D (4.5 mm pupil) between groups. Overall, Group A showed better results regarding visual and optical quality, including a lower longitudinal chromatic aberration result in comparison to Group B. Patient satisfaction evaluated with CatQuest-9SF showed that Group A achieved better outcomes, although the differences were statistically significant only for the 'Reading text on television' item (p = 0.027).
Conclusions: Both intraocular lens models showed excellent quantity of vision, optical and visual quality as well as high patient satisfaction. Despite this, the the Group A model provided slightly better outcomes than the Group B model.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1080/08164622.2021.2009737 | DOI Listing |
Clin Ophthalmol
December 2024
Department of Ophthalmology, Visual and Anatomical Sciences, Kresge Eye Institute/Wayne State University School of Medicine, Detroit, MI, USA.
Purpose: To evaluate the outcomes of scleral-fixated intraocular lenses (IOLs) implanted using either Yamane technique or Gore-Tex suture fixation, in comparison to intracapsular lens fixation, and to assess the efficacy of various lens formulas in achieving predicted refractive targets.
Patients And Methods: This study included 45 eyes from 44 patients with scleral-fixated IOLs, comprising 37 Yamane eyes and 8 Gore-Tex eyes. Preoperative refractive predictions from various formulae were compared with final postoperative refraction.
Cureus
November 2024
Ophthalmology, Moorfields Eye Hospital, London, GBR.
We report a case of spontaneous total iris avulsion that occurred during corneal wound hydration following an uneventful phacoemulsification procedure. An 86-year-old woman underwent cataract surgery on her right eye, during which a single-piece acrylic intraocular lens (Bausch and Lomb Akreos Adapt Advanced Optics, Bausch and Lomb Incorporated, Rochester, NY, USA) was implanted in the bag, and the viscoelastic material was removed. During corneal wound hydration, total iris avulsion was observed, with the iris prolapsing out of the anterior chamber through the main wound.
View Article and Find Full Text PDFEye Vis (Lond)
December 2024
Department of Ophthalmology, The Second Hospital of Jilin University, Changchun, China.
Over the past two decades, both suture and sutureless techniques for scleral fixation of intraocular lenses have seen significant advancement, driven by improvements in methodologies and instrumentation. Despite numerous reports demonstrating the effectiveness, safety, and superiority of these techniques, each approach carries with it its own drawbacks, including an elevated risk of certain postoperative complications. This article delves into various surgical techniques for scleral fixation of posterior chamber intraocular lenses, discussing their procedural nuances, benefits, drawbacks, postoperative complications, and outcomes.
View Article and Find Full Text PDFCureus
November 2024
Ophthalmology, District General Hospital Trincomalee, Trincomalee, LKA.
Introduction The Sri Lankan economic crisis that began in 2019 led to the suspension of cataract services in many districts. Although humanitarian missions were quick to supply materials, there was a lack of scientific evidence to predict the required intraocular lens power for patients with cataracts. This study aimed to assess the average lens power among patients from Trincomalee district, Sri Lanka, based on sex and age groups.
View Article and Find Full Text PDFSci Rep
December 2024
Visual Optics Lab Antwerp (VOLANTIS), Faculty of Medicine and Health Sciences, University of Antwerp, Antwerp, Belgium.
In cataract surgery, post-surgical stability of the intraocular lens plays a major role. This study aims to explore how the size and decentration of the capsulorhexis affect intraocular lens decentration and tilt by using numerical methods. Finite element models included zonules, ciliary body, capsular bag, and an IOL with two open-loop haptics were built.