The hand region is reported as the most common injury site in boxing, with more observed time loss than any other area in this sport. The amount of wrist motion, specifically flexion, has been described as contributing to these injuries, yet no literature is available to quantify wrist kinematics in boxing. This is the first paper describing wrist motion on impact in boxing. Utilising an electromagnetic tracking system, two types of shots were assessed, Jab (straight arm) and Hook (bent arm), during testing procedures with 29 elite boxers. For both shots, flexion and ulnar deviation occurred concurrent on impact, with an M and SD of 9.3 ± 1.9° and 4.7 ± 1.2° respectively for Jab shots, and 5.5 ± 1.1° and 3.3 ± 1.1° respectively for Hook shots, supporting dart throwing motion at the wrist. For both Jab & Hook, wrist motion on impact occurred within >30% and >20% respectively of total available active range of motion, with wrist angles greater in both flexion ( = 9.0, < 0.001, = 1.7) and ulnar deviation ( = 8.4, < 0.001, = 1.6) for Jab compared to Hook shots. The study provides novel and quantifiable information regarding wrist kinematics during the impact phase of punching and potentially an improved understanding of injury mechanisms in boxing.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1080/14763141.2021.2006296 | DOI Listing |
Front Psychol
January 2025
Laboratoire de Simulation et Modélisation du Mouvement, École de Kinésiologie et des Sciences de l'Activité Physique, Université de Montréal, Montréal, QC, Canada.
Introduction: Expression is a key aspect of music performance. Studies on pianists' gestures and expression have mainly documented the impact of their expressive intentions on proximal segments and head linear kinematics. It remains unclear how pianists' expressive intentions influence joint angular kinematics as well as exposure to risk factors of injury, such as poor overall posture and distal jerky movements, two kinematic factors linked to injury.
View Article and Find Full Text PDFDigit Biomark
December 2024
VivoSense, Inc., Newport Coast, CA, USA.
Introduction: Wrist-worn accelerometers can capture stepping behavior passively, continuously, and remotely. Methods utilizing peak detection, threshold crossing, and frequency analysis have been used to detect steps from wrist-worn accelerometer data, but it remains unclear how different approaches perform across a range of walking speeds and free-living activities. In this study, we evaluated the performance of four open-source methods for deriving step counts from wrist-worn accelerometry data, when applied to data from a range of structured locomotion and free-living activities.
View Article and Find Full Text PDFACS Appl Mater Interfaces
January 2025
School of Materials Science and Engineering, Henan Key Laboratory of Advanced Nylon Materials and Application, Zhengzhou University, Zhengzhou 450001, China.
Piezoelectric polymer textiles offer distinct advantages in the fabrication of wearable nanogenerators (NGs). One effective strategy to enhance the output capacity of NGs is to modulate the piezoelectric performance of the textiles. This paper focuses on further improving the piezoelectric properties of nylon-11,11 textiles through post-drawing and annealing treatments.
View Article and Find Full Text PDFSensors (Basel)
January 2025
Division of Robotics, Swinburne University of Technology, Hawthorn, VIC 3122, Australia.
Wearable motion capture gloves enable the precise analysis of hand and finger movements for a variety of uses, including robotic surgery, rehabilitation, and most commonly, virtual augmentation. However, many motion capture gloves restrict natural hand movement with a closed-palm design, including fabric over the palm and fingers. In order to alleviate slippage, improve comfort, reduce sizing issues, and eliminate movement restrictions, this paper presents a new low-cost data glove with an innovative open-palm and finger-free design.
View Article and Find Full Text PDFPLoS One
January 2025
Instituto de Ciencias Aplicadas y Tecnología (ICAT), Universidad Nacional Autónoma de México (UNAM), Ciudad de México, México.
In laparoscopy, the absence of ergonomics in the instruments affects the performance and efficiency of the surgeon, increasing the likelihood of developing musculoskeletal injuries. This article presents the development of a laparoscopic needle holder with an ergonomic handle and the experience in its use with surgeons in the intracorporeal suturing task. The handle of the laparoscopic needle holder consists of a semi-spherical piece that easily adapts to the palm of the surgeon's hand and improves the posture and ergonomics of the wrist, allowing the direct transmission of rotational movements around the longitudinal axis of the instrument towards the tip.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!