A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Joint Detection of Change Points in Multichannel Single-Molecule Measurements. | LitMetric

Joint Detection of Change Points in Multichannel Single-Molecule Measurements.

J Phys Chem B

Lewis-Sigler Institute for Integrative Genomics, Princeton University, Princeton, New Jersey 08540, United States.

Published: December 2021

Recent developments in single-molecule measurement technology have expanded the capability to measure multiple parameters. These emergent modalities provide more holistic observations of complex biomolecular processes and call for new analysis methods to detect state changes in multichannel data. Here we develop an algorithm called MULLR (MUlti-channel Log-Likelihood Ratio test) to identify change points in multichannel single-molecule measurements. MULLR is an extension of the popular single-channel implementation for change point detection based on a binary segmentation and log-likelihood ratio test framework. We validate the algorithm on simulated data and characterize the power of detection and false positive rate. We show that MULLR can identify change points in experimental multichannel data and naturally works with different noise statistics and time resolutions across channels. Further, we quantify the benefit of MULLR compared to single-channel analysis. We envision that the MULLR algorithm will be useful to a range of multiparameter single-molecule measurements.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9441227PMC
http://dx.doi.org/10.1021/acs.jpcb.1c08869DOI Listing

Publication Analysis

Top Keywords

change points
12
single-molecule measurements
12
points multichannel
8
multichannel single-molecule
8
multichannel data
8
log-likelihood ratio
8
ratio test
8
identify change
8
mullr
5
joint detection
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!