Introduction: A current challenge for endometriosis surgery is to correctly identify the localizations of disease, especially when small or hidden (occult endometriosis), and to exactly define their real extension. The use of near-infrared radiation imaging (NIR) after injection of indocyanine green (ICG) represents one of the most encouraging method. The aim of this study is to assess the diagnostic value of NIR-ICG imaging in the surgical treatment of endometriosis compared with the standard of treatment.

Material And Methods: The Gre-Endo trial is a prospective, single-arm study (NCT03332004). After exploring the operatory field using the white light (WL) mode, patients were injected with ICG and then observed in NIR mode. All suspected areas were classified and chronicled according to lesions visualized only in WL, NIR-ICG, or in the combination of both. Lesion not visualized in WL was considered as suspect occult lesion (s-OcL). In addition, a random control biopsy from an apparent negative peritoneum visualized in WL and NIR-ICG imaging was taken for all patients (control cases). All lesions removed were considered "suspect endometriosis" until pathology.

Results: Fifty-one patients were enrolled between January 2016 and October 2019. A total of 240 suspected lesions have been identified with both methods (WL + NIR-ICG). Two hundred and seven (86.2%) lesions out of the overall 240 were visualized with WL imaging, and 200 were confirmed to be pathologic (true positive for WL). The remaining 33/240 (13.75%) (false negative for WL) lesions were identified only with NIR-ICG imaging and collected as s-OcL. All 33 s-OcLs removed were confirmed to be pathologic (c-OcL = 100%). NIR-ICG vision showed PPV of 98.5%, NPV of 87.1%, Se of 87%, and Sp of 98.5%, confirming that this kind of imaging is an excellent diagnostic and screening test ( = 0.001 and = 0.835, according to McNemar's and Cohen's kappa tests, respectively).

Conclusions: The use of NIR-ICG vision alone and combined with WL showed good results in intraoperative detection rate and fluorescence-guided surgery of endometriosis. Furthermore, NIR-ICG allowed surgeons to remove occult lesions that otherwise would remain, leading to possible greater postoperative pain and a higher risk of persistence and relapse.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8634028PMC
http://dx.doi.org/10.3389/fonc.2021.737938DOI Listing

Publication Analysis

Top Keywords

nir-icg imaging
12
indocyanine green
8
treatment endometriosis
8
gre-endo trial
8
nir-icg
8
visualized nir-icg
8
lesions identified
8
confirmed pathologic
8
nir-icg vision
8
imaging
6

Similar Publications

There is a clinical need for improved intraoperative detection of endometriosis, and the use of Indocyanine Green with Near-Infrared Imaging (NIR-ICG) is a novel technique for this purpose. The aim of this review is to determine whether NIR-ICG is an effective tool for endometriosis detection and establish an evidence-based methodology for its use. This review searches Ovid MEDLINE and Embase through July 2023 and considers primary literature published in English describing the use of NIR-ICG to detect endometriosis intraoperatively.

View Article and Find Full Text PDF

Background: Indocyanine green imaging (ICG) is an expansion technology that can contribute to the development of demanding techniques such as cortical-sparing adrenalectomy (CSA). The aim of this study was to determine in which cases CSA should be performed and when total adrenalectomy should be performed instead based on ICG fluorescence. Here, we present our experience through a series of cases and videos.

View Article and Find Full Text PDF

Introduction: Anastomotic leakage (AL) is defined as the failure of complete healing or disruption of the anastomosis subsequent to rectal cancer surgery, resulting in the extravasation of intestinal contents into the intra-abdominal or pelvic cavity. It is a serious complication of rectal cancer surgery, accounting for a considerable increase in morbidity and mortality. The use of fluorescence imaging technology in surgery allows surgeons to better evaluate blood perfusion.

View Article and Find Full Text PDF

Background: The musculoskeletal system contains an extensive network of lymphatic vessels. Decreased lymph flow of the draining collecting lymphatics usually occurs in clinic after traumatic fractures. However, whether defects in lymphatic drainage can affect fracture healing is unclear.

View Article and Find Full Text PDF

The aim was to demonstrate that the technique of near infrared range/indocyanine green (NIR/ICG) could aid the detection of inguinal sentinel lymph nodes in patients with vulvar cancer, in addition to technetium-99m (Tc-99m) scanning. We present a case report of sentinel lymph node detection in a patient with vulvar cancer with two methods: Tc-99m scan and NIR/ICG. The video showed that bilateral inguinal lymph nodes were detected both by Tc gamma probe and NIR/ICG.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!