Long-term Reverse Total Shoulder Arthroplasty Outcomes: The Effect of the Inferior Shifting of Glenoid Component Fixation.

Clin Orthop Surg

Centre Orthopedique Santy, FIFA Medical Centre of Excellence, Groupe Ramsay-Generale de Sante, Hopital Prive Jean Mermoz, Lyon, France.

Published: December 2021

Backgroud: The 155° Grammont reverse shoulder replacement has a long track record of success, but also a high radiographic notching rate. The increased distance between the scapular pillar and the humeral component theoretically decreases postoperative notching. The glenoid component can be shifted inferiorly relative to the glenoid; however, there also is some concern that shifting the glenoid component too far inferiorly (inferior glenoid component overhang > 3.5 mm) may compromise long-term stability of the glenoid component. This study was conducted to determine if clinical outcomes, scapular notching, and complications vary with more inferior placement of the glenoid component.

Methods: A retrospective analysis of prospectively collected data was performed in order to compare radiographic outcomes (notching rate and signs of glenoid loosening or component disassembly) and clinical outcomes (range of motion, Constant score, subjective shoulder value, and complication rate) of all patients who underwent reverse shoulder replacement with the glenosphere positioned either flush with the inferior rim of the glenoid (flush group) or with at least 3.5 mm of inferior overhang (overhang group) at a minimum follow-up of 60 months. Ninety-seven patients ultimately met the inclusion criteria, with 41 patients with flush glenoid component and 56 patients with at least 3.5 mm of inferior overhang.

Results: Average follow-up was 97.8 months. The overhang group had a lower rate of radiographic notching (37% vs. 82.5%, < 0.05), better clinical outcomes (improvement in Constant score: +40 vs. +32, = 0.036), and higher subjective shoulder value (79 vs. 69, = 0.026) than the flush group. No difference in complications between groups was found.

Conclusions: In this study, at least 3.5 mm of inferior glenosphere overhang relative to the inferior rim of the glenoid was associated with the lower notching rate without negative effect on the clinical outcomes in 155° Grammont-style reverse shoulder replacement. Therefore, no increase in complications should be expected when using this surgical technique.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8609210PMC
http://dx.doi.org/10.4055/cios20245DOI Listing

Publication Analysis

Top Keywords

glenoid component
24
clinical outcomes
16
reverse shoulder
12
shoulder replacement
12
notching rate
12
glenoid
11
inferior
8
shifting glenoid
8
component
8
radiographic notching
8

Similar Publications

Background: The incidence of primary reverse total shoulder arthroplasty (rTSA) and the prevalence of obesity have increased in the United States. Despite this, the literature assessing the effect of morbid obesity (body mass index≥40 kg/m) on perioperative surgical outcomes remains inconsistent.

Methods: A retrospective review of consecutive elective primary rTSA cases from January 2016 through September 2023 at a single tertiary referral center was performed.

View Article and Find Full Text PDF

Humeral and Glenoid Component Malposition in Revision Shoulder Arthroplasty: A Retrospective, Cross-sectional Study.

J Shoulder Elbow Surg

January 2025

Department of Orthopedic Surgery, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, SUNY, Buffalo, NY, USA.

Background: The purpose of this study was to assess the incidence of glenoid and humeral component malposition in failed primary shoulder arthroplasty requiring revision. We hypothesized that glenoid and humeral component malposition would be a prevalent feature in cases requiring revision arthroplasty for primary anatomic TSA, primary RSA, and primary hemiarthroplasty procedures.

Methods: A retrospective cross-sectional study was performed focusing on identifying the incidence of malpositioned components in shoulder arthroplasty in quantitative and qualitative reviews.

View Article and Find Full Text PDF

Introduction: Periprosthetic joint infections (PJIs) of the shoulder complicate approximately 0.7% of primary and 15.4% of revision shoulder arthroplasties.

View Article and Find Full Text PDF

Background: While stress shielding and adaptive bone changes around the humeral component are often observed after shoulder arthroplasty, the potential causative factors and clinical significance of these findings at mid-term follow-up have not been well elucidated. The purpose of this study was to investigate the frequency, patterns and clinical significance of radiographic findings around the humeral component of total shoulder arthroplasty (TSA) and hemiarthroplasty (HA) at minimum 4-year follow-up.

Methods: The 6-week and minimum 4-year radiographs of patients who underwent HA and TSA were evaluated for filling ratios, changes in the humeral bone surrounding the component, and component shift or subsidence.

View Article and Find Full Text PDF

Background: Anatomic total shoulder arthroplasty are highly successful procedures for treatment of glenohumeral arthritis to reduce pain, improve range of motion, and overall quality of life. However, the long-term survivorship of the implant systems is less widely documented in the existing literature. The purpose of this study was to establish the long-term patient outcomes and identify factors influencing the postoperative implant survivorship of total anatomic shoulder arthroplasty devices/procedures utilizing the short-stemmed prosthesis and hybrid glenoid components of the Comprehensive Shoulder System (Zimmer Biomet, Warsaw, IN, USA) at an average of ten years.